87299
1.INSPECT HEATER RELAY (for Manual Cooler System)
| *a | Component without harness connected
(Heater Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage is not applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Battery voltage is applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the heater relay.
85934
2.INSPECT MAGNET-CLUTCH RELAY
| *a | Component without harness connected
(Magnet-clutch Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the magnet-clutch relay.
87346K
3.INSPECT PTC HEATER RELAY(PTC HTR NO. 1) (w/ PTC Heater)
| *a | Component without harness connected
(PTC Heater Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the PTC heater relay (PTC HTR No. 1).
87346L
4.INSPECT PTC HEATER RELAY(PTC HTR NO. 2, NO. 3) (w/ PTC Heater)
| *a | Component without harness connected
(PTC Heater Relay) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Battery voltage is applied between terminals 1 and 2 | Below 1 Ω |