Home › Drivetrain › AXLE AND DIFFERENTIAL › AUTOMATIC DISCONNECTING DIFFERENTIAL ACTUATOR
RM3270E _52 Drivetrain _041686 AXLE AND DIFFERENTIAL _0217075 AUTOMATIC DISCONNECTING DIFFERENTIAL ACTUATOR G

AXLE AND DIFFERENTIAL  AUTOMATIC DISCONNECTING DIFFERENTIAL ACTUATOR  INSPECTION  


PROCEDURE

Hide 41400B 1.INSPECT DIFFERENTIAL MOTOR ACTUATOR ASSEMBLY

a.
C237690C05
2.313,3 3.073,3 true 2.51,3.135 2.76,3.135 2.76,3.135 2.76,3 false 2.052,3.573 1.427,3.573 false 2.448,3.531 2.844,3.531 false 1.76,0.729 1.76,0.146 1.76,0.146 2.052,0.146 true 1.313,0.198 1.51,0.198 1.51,0.198 1.51,0.719 true 1.74,1.313 1.385,1.313 1.385,1.313 1.385,0.885 true 0.5,0.719 1.031,0.719 true 3.104,2.906 3.26,3.063 0.156,0.156 10 false *1 1.24,3.479 1.396,3.635 0.156,0.156 10 false *a 2.865,3.438 3.021,3.594 0.156,0.156 10 false *b 2.208,4.177 2.656,4.344 0.448,0.167 10 false *c 2.125,0.063 2.583,0.26 0.458,0.198 10 false ADD 0.969,0.115 1.427,0.313 0.458,0.198 10 false GND 1.813,1.229 2.198,1.479 0.385,0.25 10 false DL2 0.198,0.646 0.656,0.844 0.458,0.198 10 false DL1
*1 Shift Fork
*a 2WD Side
*b 4WD Side
*c 12 mm (0.472 in.)


Measure the resistance between terminals 1 and 2.

Standard:

0.1 to 100 Ω



b.

Measure the resistance between terminal 1 or 2 and body ground.

Standard:

5 MΩ or more


If the result is not as specified, replace the differential motor actuator.


c.

Check the actuator using one of the following methods.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Measurement Condition Specified Condition
3 (ADD) - 4 (GND) Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Below 1 Ω
3 (ADD) - 4 (GND) Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
10 kΩ or higher
4 (GND) - 5 (DL2) Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Below 1 Ω
4 (GND) - 5 (DL2) Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
10 kΩ or higher
4 (GND) - 6 (DL1) Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Below 1 Ω
4 (GND) - 6 (DL1) Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
10 kΩ or higher


If the result is not as specified, replace the differential motor actuator assembly.


ii.

Check the actuator status.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
2WD → 4WD
Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1
4WD → 2WD


If the result is not as specified, replace the differential motor actuator assembly.