Home › General › SPECIFICATIONS › 1GD-FTV EMISSION CONTROL
RM3270E _V1 General _041724 SPECIFICATIONS _0193808 1GD-FTV EMISSION CONTROL F

SPECIFICATIONS  1GD-FTV EMISSION CONTROL  SERVICE DATA  


NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground
2 - Body ground
20°C (68°F) 1 MΩ or higher

EXHAUST GAS TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 89.3 to 159.8 kΩ

EXHAUST FUEL ADDITION INJECTOR
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 7.1 to 7.9 Ω