Home › Vehicle Interior › HEATING / AIR CONDITIONING › RELAY › from 2016.01
RM3270E _58 Vehicle Interior _041713 HEATING / AIR CONDITIONING _0200004 RELAY G

HEATING / AIR CONDITIONING  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 87299 1.INSPECT HEATER RELAY (for Manual Air Conditioning System, Manual Cooler System)

a.
B106753C03
2.51,0.802 2.51,0.615 true 2.854,1.177 3.042,1.177 true 2.5,1.521 2.5,1.719 true 2.073,1.208 2.073,1.74 true 2.479,1.042 1.802,1.042 true 0.813,0.146 0.906,0.344 0.094,0.198 10 false 4 0.333,0.792 0.427,0.99 0.094,0.198 10 false 5 1.271,0.792 1.365,0.99 0.094,0.198 10 false 3 0.333,1.604 0.427,1.802 0.094,0.198 10 false 1 1.281,1.594 1.375,1.792 0.094,0.198 10 false 2 1.677,0.969 1.771,1.167 0.094,0.198 10 false 4 3.083,1.094 3.177,1.292 0.094,0.198 10 false 5 2.031,1.75 2.125,1.948 0.094,0.198 10 false 3 2.479,0.438 2.573,0.635 0.094,0.198 10 false 1 2.479,1.75 2.573,1.948 0.094,0.198 10 false 2 0.042,0.01 0.354,0.167 0.313,0.156 10 false *a
*a Component without harness connected
(Heater Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 4 Battery voltage is not applied between terminals 1 and 2 Below 1 Ω
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 4 Battery voltage is applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the heater relay.


Hide 85934 2.INSPECT MAGNET-CLUTCH RELAY

a.
B060778C16
2.229,0.656 2.073,0.75 false 2.563,0.76 2.406,0.854 false 2.323,1.167 2.167,1.26 false 2.458,1.49 2.302,1.583 false 0.208,1.333 0.365,1.531 0.156,0.198 10 false 1 1.219,1.302 1.375,1.5 0.156,0.198 10 false 2 0.229,0.771 0.385,0.969 0.156,0.198 10 false 3 1.208,0.771 1.365,0.969 0.156,0.198 10 false 5 2.24,0.552 2.396,0.75 0.156,0.198 10 false 1 2.292,0.802 2.448,1 0.156,0.198 10 false 2 2.021,1.219 2.177,1.417 0.156,0.198 10 false 5 2.542,1.354 2.698,1.552 0.156,0.198 10 false 3 0.063,0.063 0.375,0.219 0.313,0.156 10 false *a
*a Component without harness connected
(Magnet-clutch Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the magnet-clutch relay.



Hide 87346K 3.INSPECT PTC HEATER RELAY(PTC HTR NO. 1) (w/ PTC Heater)

a.
E287491C02
1.073,1.135 1.292,0.833 1.292,0.833 1.448,0.833 false 0.792,0.865 0.844,0.479 0.844,0.479 0.979,0.479 false 0.542,1.156 0.354,0.844 0.354,0.844 0.24,0.844 false 0.813,1.531 0.844,1.885 0.844,1.885 0.958,1.885 false 1.802,0.76 1.958,0.958 0.156,0.198 10 false 3 3.125,0.76 3.281,0.958 0.156,0.198 10 false 5 1.813,1.427 1.969,1.625 0.156,0.198 10 false 1 3.135,1.417 3.292,1.615 0.156,0.198 10 false 2 1.01,1.792 1.167,1.99 0.156,0.198 10 false 3 0.115,0.75 0.271,0.948 0.156,0.198 10 false 1 1.021,0.396 1.177,0.594 0.156,0.198 10 false 5 1.5,0.74 1.656,0.938 0.156,0.198 10 false 2 0.167,0.167 0.323,0.365 0.156,0.198 10 false *a
*a Component without harness connected
(PTC Heater Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the PTC heater relay (PTC HTR No. 1).



Hide 87346L 4.INSPECT PTC HEATER RELAY(PTC HTR NO. 2, NO. 3) (w/ PTC Heater)

a.
B060778C11
2.229,0.656 2.073,0.75 false 2.563,0.76 2.406,0.854 false 2.323,1.167 2.167,1.26 false 2.458,1.49 2.302,1.583 false 0.208,1.333 0.365,1.531 0.156,0.198 10 false 1 1.219,1.302 1.375,1.5 0.156,0.198 10 false 2 0.229,0.771 0.385,0.969 0.156,0.198 10 false 3 1.208,0.771 1.365,0.969 0.156,0.198 10 false 5 2.24,0.552 2.396,0.75 0.156,0.198 10 false 1 2.292,0.802 2.448,1 0.156,0.198 10 false 2 2.021,1.219 2.177,1.417 0.156,0.198 10 false 5 2.542,1.354 2.698,1.552 0.156,0.198 10 false 3 0.073,0.063 0.385,0.219 0.313,0.156 10 false *a
*a Component without harness connected
(PTC Heater Relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the PTC heater relay (PTC HTR No. 2, No. 3).



Hide 85934A 5.INSPECT CONDENSER FAN RELAY (w/ Condenser Fan)

a.
B060778C16
2.229,0.656 2.073,0.75 false 2.563,0.76 2.406,0.854 false 2.323,1.167 2.167,1.26 false 2.458,1.49 2.302,1.583 false 0.208,1.333 0.365,1.531 0.156,0.198 10 false 1 1.219,1.302 1.375,1.5 0.156,0.198 10 false 2 0.229,0.771 0.385,0.969 0.156,0.198 10 false 3 1.208,0.771 1.365,0.969 0.156,0.198 10 false 5 2.24,0.552 2.396,0.75 0.156,0.198 10 false 1 2.292,0.802 2.448,1 0.156,0.198 10 false 2 2.021,1.219 2.177,1.417 0.156,0.198 10 false 5 2.542,1.354 2.698,1.552 0.156,0.198 10 false 3 0.063,0.063 0.375,0.219 0.313,0.156 10 false *a
*a Component without harness connected
(Condenser Fan relay)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Battery voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage is applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the condenser fan relay.