Home › Vehicle Interior › HEATING / AIR CONDITIONING › PRESSURE SWITCH › from 2016.01
RM3270E _58 Vehicle Interior _041713 HEATING / AIR CONDITIONING _0200006 PRESSURE SWITCH G

HEATING / AIR CONDITIONING  PRESSURE SWITCH  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 88645H 1.INSPECT NO. 1 PRESSURE SWITCH (w/o Condenser Fan)

a.

Disconnect the connector.


b.
E075701C04
0.938,0.906 1.219,0.906 1.219,0.906 1.552,1.333 true 2.365,0.896 2.125,0.896 2.125,0.896 1.865,1.323 true 0.042,0.042 0.24,0.25 0.198,0.208 10 false *a 0.708,0.813 1.021,1.01 0.313,0.198 10 false S+ 2.438,0.823 2.75,1.021 0.313,0.198 10 false S-
*a Front view of wire harness connector
(No. 1 Pressure Switch)


Using a service wire, connect terminals 1 (S+) and 2 (S-) of the No. 1 pressure switch connector on the vehicle wire harness side.


c.

Start the engine.


d.

Turn the A/C switch on and check that the magnet clutch turns on.


e.

Check that the magnet clutch turns off when disconnecting terminals 1 (S+) and 2 (S-).

OK:
Measurement Condition Specified Condition
Terminals 1 (S+) and 2 (S-) connected Magnet clutch turns on
Terminals 1 (S+) and 2 (S-) disconnected Magnet clutch turns off


If the result is not as specified, replace the No. 1 pressure switch.


Hide 88645H 2.INSPECT NO. 1 PRESSURE SWITCH (w/ Condenser Fan)

a.

Disconnect the connector.


b.

Start the engine.


c.

Turn the A/C switch on and check that the magnet clutch turns on.


d.
E341804C01
1.74,1.219 2.583,1.219 true 1.729,0.875 2.573,0.875 true 0.083,0.083 0.396,0.24 0.313,0.156 10 false *a 1.604,2.156 1.917,2.313 0.313,0.156 10 false *d 0.615,2.5 0.927,2.656 0.313,0.156 10 false *e 0.76,2.688 1.073,2.844 0.313,0.156 10 false *f 1.208,2.542 1.552,2.792 0.344,0.25 10 false *g 2.635,2.677 2.948,2.833 0.313,0.156 10 false *h 2.75,2.51 3.063,2.667 0.313,0.156 10 false *e 2.615,0.792 3,0.979 0.385,0.188 10 false (S+) 2.635,1.146 3.021,1.333 0.385,0.188 10 false (S-) 0.896,2.167 1.115,2.323 0.219,0.156 10 false *c 2.354,2.177 2.667,2.333 0.313,0.156 10 false *b
*a Component without harness connected
(No. 1 Pressure Switch)
*b High Pressure Side
*c Low Pressure Side
*d ON (Continuity)
*e OFF (No Continuity)
*f 176 to 216 kPa (1.8 to 2.2 kgf/cm2, 26 to 31 psi)
*g 196 to 250 kPa (2.0 to 2.5 kgf/cm2, 28 to 36 psi)
*h 3140 to 3340 kPa (32.0 to 34.1 kgf/cm2, 455 to 484 psi)


High Pressure Side, Low Pressure Side (Magnet Clutch Control):

Measure the resistance according to the value(s) in the table below.

OK:
Measurement Condition Refrigerant Volume Specified Condition
1 (S+) - 4 (S-) See the graph Below 1 Ω
1 (S+) - 4 (S-) 10 kΩ or higher


If the result is not as specified, replace the No. 1 pressure switch.


e.
E341805C01
0.802,1.135 1.333,1.135 true 1.969,1.125 2.438,1.125 true 0.083,0.063 0.396,0.219 0.313,0.156 10 false *a 1.865,2.156 2.177,2.313 0.313,0.156 10 false *b 1.083,2.49 1.396,2.646 0.313,0.156 10 false *c 1.198,2.667 1.51,2.823 0.313,0.156 10 false *d 1.854,2.667 2.167,2.823 0.313,0.156 10 false *e 2.469,1.042 2.865,1.25 0.396,0.208 10 false (S+) 0.542,1.052 0.906,1.25 0.365,0.198 10 false (S-)
*a Component without harness connected
(No. 1 Pressure Switch)
*b ON (Continuity)
*c OFF (No Continuity)
*d 111 to 135 kPa (1.1 to 1.4 kgf/cm2, 16 to 20 psi)
*e 144 to 160 kPa (1.5 to 1.6 kgf/cm2, 21 to 23 psi)


Middle Pressure Side (Condenser Fan Control):

Measure the resistance according to the value(s) in the table below.

OK:
Measurement Condition Refrigerant Volume Specified Condition
2 (S+) - 3 (S-) See the graph Below 1 Ω
2 (S+) - 3 (S-) 10 kΩ or higher


If the result is not as specified, replace the No. 1 pressure switch.