Home › Engine / Hybrid System › 2GD-FTV ENGINE CONTROL › INTAKE AIR TEMPERATURE SENSOR › from 2016.01
RM3270E _51 Engine / Hybrid System _048922 2GD-FTV ENGINE CONTROL _0236352 INTAKE AIR TEMPERATURE SENSOR G

2GD-FTV ENGINE CONTROL  INTAKE AIR TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 89424D 1.INSPECT INTAKE AIR TEMPERATURE SENSOR

a.

Partially immerse the intake air temperature sensor in water and warm up the water.


b.

Measure the resistance according to the value(s) in the table below.

A203929C02
5.865,1.354 5.708,1.354 5.708,1.354 5.458,1.708 false 4.625,0.802 4.948,1.01 0.323,0.208 8 false 30 4.625,0.948 4.948,1.156 0.323,0.208 8 false 20 4.625,1.146 4.948,1.354 0.323,0.208 8 false 10 4.625,1.396 4.948,1.604 0.323,0.208 8 false 5 4.625,1.573 4.948,1.781 0.323,0.208 8 false 3 4.625,1.708 4.948,1.917 0.323,0.208 8 false 2 4.625,1.927 4.948,2.135 0.323,0.208 8 false 1 4.625,2.469 4.948,2.677 0.323,0.208 8 false 0.2 4.625,2.323 4.948,2.531 0.323,0.208 8 false 0.3 4.625,2.156 4.948,2.365 0.323,0.208 8 false 0.5 4.625,2.688 4.948,2.896 0.323,0.208 8 false 0.1 5.135,2.969 5.313,3.156 0.177,0.188 8 false 0 5.344,2.969 5.542,3.135 0.198,0.167 8 false 20 5.594,2.969 5.802,3.146 0.208,0.177 8 false 40 5.854,2.969 6.052,3.156 0.198,0.188 8 false 60 6.115,2.969 6.333,3.156 0.219,0.188 8 false 80 6.396,2.979 6.667,3.156 0.271,0.177 8 false 100 4.844,2.969 5.073,3.135 0.229,0.167 8 false -20 6.573,3.344 7.125,3.552 0.552,0.208 10 false °C (°F) 4.844,3.104 5.073,3.281 0.229,0.177 8 false (-4) 5.323,3.104 5.594,3.302 0.271,0.198 8 false (68) 5.563,3.104 5.896,3.302 0.333,0.198 8 false (104) 5.844,3.104 6.167,3.313 0.323,0.208 8 false (140) 6.115,3.104 6.458,3.313 0.344,0.208 8 false (176) 6.406,3.104 6.75,3.313 0.344,0.208 8 false (212) 4.135,1.625 4.448,1.781 0.313,0.156 10 false *b 5.552,3.458 5.865,3.615 0.313,0.156 10 false *c 5.938,1.271 6.25,1.427 0.313,0.156 10 false *d 1.979,0.448 2.292,0.604 0.313,0.156 10 false *a 4.354,0.583 4.76,0.781 0.406,0.198 10 false kΩ 5.073,3.104 5.333,3.313 0.26,0.208 8 false (32)
*a Component without harness connected (Intake Air Temperature Sensor) *b Resistance
*c Temperature *d Acceptable Range


Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.21 to 2.65 kΩ
60°C (140°F) 0.54 to 0.62 kΩ


CAUTION:
·

Do not put your hands in the water warmed up during the inspection.

·

Touching the hot water may result in burns.



NOTICE:

When checking the intake air temperature sensor in water, do not allow water to contact the terminals. After completing the check, dry the intake air temperature sensor.


If the result is not as specified, replace the intake air temperature sensor.