Refer to the system description for DTC P2714.
Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FE)>P2714
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2716 | Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1 trip detection logic). | ·
Open or short in shift solenoid valve SLT circuit ·
Shift solenoid valve SLT ·
ECM |
Comes on | DTC stored |
When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store the DTC.
Perform registration and/or initialization when parts related to the automatic transmission are replaced.
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Start the engine.
Check for DTCs again.
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 13 (SLT+) - 14 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 13 (SLT+) - Body ground | Always | 10 kΩ or higher |
| 14 (SLT-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C148-5 (SLT+) - C148-4 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| C148-5 (SLT+) - Body ground | Always | 10 kΩ or higher |
| C148-4 (SLT-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Shift Solenoid Valve SLT |
Remove shift solenoid valve SLT.
Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) with a 21 W bulb → Terminal 1 ·
Battery negative (-) → Terminal 2 |
Valve moves and makes an operating noise |
| Proceed to |
|---|
| OK |
| NG |
OK
NG