Home › Power Source / Network › 2GD-FTV BATTERY / CHARGING › CHARGING SYSTEM › from 2016.01
RM3270E _57 Power Source / Network _048964 2GD-FTV BATTERY / CHARGING _0239208 CHARGING SYSTEM U

2GD-FTV BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM


A340466E01
0.531,0.438 0.969,0.677 0.438,0.24 1.74,0.438 2.177,0.677 0.438,0.24 2.844,0.438 3.281,0.677 0.438,0.24 3.885,0.438 4.323,0.677 0.438,0.24 5,0.438 5.438,0.677 0.438,0.24 6.156,0.438 6.594,0.677 0.438,0.24 1.844,0.469 2.156,0.667 0.313,0.198 10 false C39 0.635,0.469 0.948,0.667 0.313,0.198 10 false C38 2.938,0.469 3.25,0.667 0.313,0.198 10 false C40 3.99,0.469 4.302,0.667 0.313,0.198 10 false C41 5.083,0.469 5.396,0.667 0.313,0.198 10 false G49 6.25,0.469 6.563,0.667 0.313,0.198 10 false G50

HINT:

Since the ECM uses waterproof connectors, the resistance cannot be inspected directly. Standard resistances are indicated for reference only.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
C41-7 (LIN) - Body ground P - Body ground LIN communication line Engine switch off
(while LIN communication is stopped)
10 kΩ or higher