A750F AUTOMATIC TRANSMISSION / TRANSAXLE  TRANSMISSION WIRE  INSPECTION  


PROCEDURE

Hide 82125J 1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)

C214326C60
2.219,0.979 2.51,0.438 true 2.146,1.323 2.385,1.781 true 2.073,0.979 1.781,0.438 true 2,1.323 1.75,1.792 true 2.396,1.813 2.813,1.979 0.417,0.167 10 false OT2+ 1.51,1.823 1.844,1.99 0.333,0.167 10 false OT+ 0.104,0.083 0.385,0.292 0.281,0.208 10 false *a 2.49,0.229 2.885,0.396 0.396,0.167 10 false OT2- 1.563,0.219 1.885,0.385 0.323,0.167 10 false OT-
*a Component without harness connected
(Transmission Wire)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection ATF Temperature Specified Condition
2 (OT-) - 10 (OT+) Always 79 Ω to 156 kΩ
2 (OT-) - Body ground Always 10 kΩ or higher
10 (OT+) - Body ground Always 10 kΩ or higher
1 (OT2-) - 9 (OT2+) Always 25 Ω to 156 kΩ
1 (OT2-) - Body ground Always 10 kΩ or higher
9 (OT2+) - Body ground Always 10 kΩ or higher


HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


Resistance (Reference):
ATF Temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ


If the result is not as specified, replace the transmission wire.