Home › Power Source / Network › 5L-E BATTERY / CHARGING › GENERATOR › from 2016.01
RM3270E _57 Power Source / Network _048967 5L-E BATTERY / CHARGING _0239363 GENERATOR A

5L-E BATTERY / CHARGING  GENERATOR  INSTALLATION  


PROCEDURE

Hide 27020 1.INSTALL GENERATOR ASSEMBLY

a.

Temporarily install the generator assembly with the 2 bolts.


b.

Connect the vacuum pump oil outlet hose.


c.

Install 2 new gaskets and the vacuum pump oil inlet hose with the union bolt.

Torque:
14 N*m (143 kgf*cm, 10 ft.*lbf)


d.

Connect the vacuum pump hose.


e.

Attach the vacuum pump oil inlet hose to the cord clip.


f.

Install the generator wire with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


g.

Install the terminal cap.


h.

Connect the generator connector.


Hide 2.INSTALL COMPRESSOR ASSEMBLY WITH MAGNETIC CLUTCH

Hide 16361A 3.INSTALL FAN AND GENERATOR V BELT

Hide 4.CONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION