25860
1.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 33 to 39 Ω |
| 1 - Body ground | Always | 1 MΩ or higher |
| 2 - Body ground |
If the result is not as specified, replace the vacuum switching valve assembly.
Check the VSV operation.
| *a | Filter |
| *b | Port E |
|
Air |
Check that air flows from port E to the filter.
If the result is not as specified, replace the vacuum switching valve assembly.
| *a | Port E |
| *b | Port F |
|
Air |
Apply battery voltage across the terminals.
Check that air flows from port E to port F.
If the result is not as specified, replace the vacuum switching valve assembly.