Home › Engine / Hybrid System › 1KD-FTV INTAKE / EXHAUST › INTAKE MANIFOLD › from 2016.01
RM3270E _51 Engine / Hybrid System _048918 1KD-FTV INTAKE / EXHAUST _0243295 INTAKE MANIFOLD G

1KD-FTV INTAKE / EXHAUST  INTAKE MANIFOLD  INSPECTION  


PROCEDURE

Hide 17111 1.INSPECT INTAKE MANIFOLD

NOTICE:
A149794

Do not adjust the adjusting screw or 2 actuator installation bolts.


a.
A149796C02
0.355,0.035 0.534,0.188 0.179,0.153 10 *a 0.317,0.118 0.205,0.118 0.205,0.118 0.205,1.699 false 0.205,1.699 0.824,2.035 false
*a Disconnect


Disconnect the vacuum hose from the actuator.


b.

Check the operation of the swirl control valve.

i.

Check that the valve is fully opened under normal conditions.


ii.

Connect a vacuum pump to the control valve. Check that the valve is fully closed when a negative pressure of 35 kPa (263 mmHg, 10 in.Hg) is applied.


iii.

Leave it for 1 minute and check that the vacuum pump needle does not move.

If the result is not as specified, replace the intake manifold.



Hide 2.INSPECT VACUUM SWITCHING VALVE (for Swirl Control Valve)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground
2 - Body ground
20°C (68°F) 10 kΩ or higher


If the result is not as specified, replace the intake manifold.


b.
G037162C11
2.938,0.833 2.844,0.833 2.844,0.833 2.458,1.125 true 0.813,0.948 0.906,0.948 0.906,0.948 1.125,1.104 false 3.01,0.75 3.24,0.969 0.229,0.219 10 false *b 0.615,0.885 0.875,1.115 0.26,0.229 10 false *a
*a Port E
*b Filter
V100135

Airflow


Check the operation according to the value(s) in the table below.

i.

Check that air flows from port E to the filter.

If the result is not as specified, replace the intake manifold.


ii.
A110309C08
1.854,0.625 1.76,0.625 1.76,0.625 1.479,1.396 true 2.104,0.854 2.01,0.854 2.01,0.854 1.573,1.458 true 1.063,1.615 0.969,1.615 0.969,1.615 0.823,1.729 false 0.229,1.802 0.323,1.802 0.323,1.802 0.5,1.875 false 0.948,1.156 1.104,0.958 false 1.094,0.969 1.167,0.906 false 1.906,0.531 2.115,0.719 0.208,0.188 10 false 2 2.177,0.771 2.385,0.969 0.208,0.198 10 false 1 1.115,1.51 1.365,1.708 0.25,0.198 10 false *a 0.063,1.708 0.292,1.875 0.229,0.167 10 false *b
*a Port E
*b Port F
V100135

Airflow


Apply battery voltage across the terminals.


iii.

Check that air flows from port E to port F.