Home › Drivetrain › AC60F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) › from 2016.01
RM3270E _52 Drivetrain _041680 AC60F AUTOMATIC TRANSMISSION / TRANSAXLE _0239142 AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE) C

AC60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)  P0741  Torque Converter Clutch Solenoid Performance (Shift Solenoid Valve SL)  


SYSTEM DESCRIPTION

The ECM uses signals from the throttle position sensor, air-flow meter, transmission revolution sensor (NT), transmission revolution sensor (SP2) and crankshaft position sensor to help determine the engagement timing of the lock-up clutch. The ECM monitors the engagement of the clutch using the transmission revolution sensor (NT), transmission revolution sensor (SP2) and crankshaft position sensor. Then the ECM compares the engagement condition of the lock-up clutch with the lock-up schedule in the ECM memory to detect shift solenoid valve SL, transmission valve body assembly and torque converter assembly mechanical problems.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0741 Torque Converter Clutch Solenoid Performance (Shift Solenoid Valve SL) Lock-up does not occur when requested (2 trip detection logic).
·

Shift solenoid valve SL remains closed

·

Transmission wire

·

Transmission valve body assembly is blocked

·

Torque converter assembly

·

Automatic transmission assembly (clutch, brake or gear etc.)

·

Line pressure is too low


Comes on DTC stored

MONITOR DESCRIPTION

Torque converter lock-up is controlled by the ECM based on the transmission revolution sensor (NT), transmission revolution sensor (SP2), engine speed, engine load, engine temperature, vehicle speed, transmission fluid temperature, and gear selection. The ECM determines the lock-up status of the torque converter by comparing the engine speed (NE) to the input turbine speed (NT). The ECM calculates the actual transmission gear by comparing the input turbine speed (NT) to the output shaft speed (SP2).

When conditions are appropriate, the ECM requests "lock-up" by applying control voltage to shift solenoid valve SL. When shift solenoid valve SL is turned on, it applies pressure to the lock-up relay valve and locks the torque converter.

If the ECM detects no lock-up after lock-up has been requested or if it detects lock-up when it is not requested, the ECM interprets this as a fault in shift solenoid valve SL or lock-up system performance.

The ECM will illuminate the MIL and store the DTC.

HINT:

Example:

When any of the following is met, the system judges it as a malfunction.

·

There is a difference in rotation speed between the input side (engine speed) and output side (input turbine speed) of the torque converter when the ECM commands lock-up. (Engine speed is at least 70 rpm more than the input turbine speed.)

·

There is no difference in rotation speed between the input side (engine speed) and output side (input turbine speed) of the torque converter when the ECM commands lock-up off. (The difference between engine speed and input turbine speed is less than 35 rpm.)



CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transmission are replaced.

Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM(for 1GR-FE)>INITIALIZATION


HINT:

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

2.

Turn the ignition switch off.

3.

Perform step (*1) again.



ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / Engine and ECT / Active Test.


g.

According to the display on the GTS, perform the Active Test.

Powertrain > Engine > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Activate the Lock Up Controls the shift solenoid valves SLU and SL to set the automatic transmission to the lock-up condition. ON/OFF Can be used to check shift solenoid valves SLU and SL operation.
[Vehicle Condition]
·

Throttle valve opening angle: Less than 30%

·

Vehicle speed: 80 km/h (50 mph) or more


Powertrain > Engine > Active Test
Tester Display
Activate the Lock Up
50004 234 115
HINT:

This test can be conducted when the vehicle speed is 80 km/h (50 mph) or more.



h.

Lightly depress the accelerator pedal and check that the engine speed does not change abruptly.

HINT:
·

When changing the accelerator pedal opening angle while driving, if the engine speed does not change, lock-up is on.

·

Slowly release the accelerator pedal in order to decelerate, but do not fully release the pedal. (Fully releasing the pedal will close the throttle valve and lock-up may be turned off.)


C159073E17
4.542,2.188 5.521,1.958 5.521,1.958 5.583,1.958 false 5.198,2.229 5.542,2.615 5.542,2.615 5.604,2.615 false 0.656,2.708 1.865,3.063 1.208,0.354 10 false Engine Speed 0.594,1.719 1.698,2.104 1.104,0.385 10 false Accelerator Pedal Fully Released 0.594,1.021 1.719,1.5 1.125,0.479 10 false Accelerator Pedal Opening Angle 4.99,3.125 5.438,3.323 0.448,0.198 10 false Time 5.667,1.865 6.656,2.063 0.99,0.198 10 false Lock-up OFF 5.656,2.49 6.615,2.688 0.958,0.198 10 false Lock-up ON




PROCEDURE

1.CHECK OTHER DTCS OUTPUT (IN ADDITION TO DTC P0741)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

Powertrain > Engine > Trouble Codes
50001 234

e.

Read the DTCs using the GTS.

Result:
Result Proceed to
Only DTC P0741 is output A
P0741 and other DTCs are output B


HINT:

If any other codes besides P0741 are output, perform the troubleshooting for those DTCs first.




A

2.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)

B

2.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
a.
C319326C02
2.688,1.76 2.458,0.99 true 0.156,0.094 0.469,0.292 0.313,0.198 10 false *a 2.635,1.833 2.948,2.031 0.313,0.198 10 false SL
*a Component without harness connected
(Transmission Wire)


Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (SL) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

3.INSPECT SHIFT SOLENOID VALVE SL (OPERATION)

NG

6.INSPECT SHIFT SOLENOID VALVE SL (RESISTANCE)
3.INSPECT SHIFT SOLENOID VALVE SL (OPERATION)
a.
C320235C01
0.208,0.198 0.521,0.354 0.313,0.156 10 false *1 1.771,1.604 2.083,1.76 0.313,0.156 10 false (+) 2.594,1.604 2.906,1.76 0.313,0.156 10 false (-)
*1 Shift Solenoid Valve SL


Remove shift solenoid valve SL.

Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY


b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SL connector

·

Battery negative (-) → Shift solenoid valve SL body


Valve moves and makes an operating noise



Result:
Proceed to
OK
NG



OK

4.INSPECT TRANSMISSION VALVE BODY ASSEMBLY

NG

4.INSPECT TRANSMISSION VALVE BODY ASSEMBLY
a.

Check the transmission valve body assembly.

Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY

OK:

There is no foreign matter on each valve and they operate smoothly.



Result:
Proceed to
OK
NG



OK

5.INSPECT TORQUE CONVERTER ASSEMBLY

NG

REPAIR OR REPLACE TRANSMISSION VALVE BODY ASSEMBLY

5.INSPECT TORQUE CONVERTER ASSEMBLY
a.

Check the torque converter assembly.

Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>TORQUE CONVERTER AND DRIVE PLATE>INSPECTION

OK:

The torque converter operates normally.



Result:
Proceed to
OK
NG



OK

NG

6.INSPECT SHIFT SOLENOID VALVE SL (RESISTANCE)
a.
C320236C01
0.24,0.313 0.552,0.469 0.313,0.156 10 false *1
*1 Shift Solenoid Valve SL


Remove shift solenoid valve SL.

Click hereDrivetrain>AC60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG