This DTC is stored when a malfunction in the ACC output circuit is detected. The ACC output circuit is the circuit that goes from the ACC output terminal of the certification ECU (smart key ECU assembly) to the ACC relay.
When the cable is disconnected and reconnected to the negative (-) battery terminal, the power source mode returns to the state it was in before the cable was disconnected.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Note |
|---|---|---|---|---|
| B2274 | ACC Monitor Malfunction | Malfunction in the ACC relay circuit in the certification ECU (smart key ECU assembly) or in the external circuit (1-trip detection logic*1).
|
·
SMART fuse ·
ACC relay (Instrument panel junction block assembly) ·
Certification ECU (smart key ECU assembly) ·
Harness or connector |
Wait 10 seconds after turning the engine switch on (ACC) or on (IG), and then wait another 10 seconds after turning the engine switch off.
|
*1: Only detected while a malfunction is present.
*2: for Automatic Transmission
*3: for Manual Transmission
| Vehicle Condition | |||
| Pattern 1 | Pattern 2 | ||
| Malfunction Statu | Malfunction in the ACC relay circuit in the certification ECU (smart key ECU assembly) | ○ | - |
| Malfunction in the ACC relay circuit in the external circuit | - | ○ | |
| Detection Time | - | - | |
| Trip Count | 1-trip | 1-trip | |
If the conditions match either of these patterns, a DTC will be output.
| Vehicle Condition when Malfunction Detected | Fail-safe Function when Malfunction Detected |
|---|---|
·
If there is a malfunction due to the relay being stuck on, the ACC relay does not turn off even though the engine switch is off. ·
If there is a malfunction due to the relay being stuck off, the ACC relay does not turn on even though the engine switch is on (ACC).
|
- |
| DTC No. | Data List Item | Active Test Item |
|---|---|---|
| B2274 | Power Source Control
·
ACC Relay Monitor Starting Control
·
Ignition |
- |
When using the GTS with the engine switch off, connect the GTS to the DLC3 and turn a courtesy light switch on and off at intervals of 1.5 seconds or less until communication between the GTS and the vehicle begins. Then select the Model Code "KEY REGIST" under manual mode and enter the following menus: Body Electrical / Entry&Start(CAN). While using the GTS, periodically turn a courtesy light switch on and off at intervals of 1.5 seconds or less to maintain communication between the GTS and the vehicle.
The smart entry and start system (for Start Function) uses a multiplex communication system (LIN communication system) and the CAN communication system. Inspect the communication function by following How to Proceed with Troubleshooting (Click hereVehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>SMART ENTRY AND START SYSTEM(for Start Function)>HOW TO PROCEED WITH TROUBLESHOOTING). Troubleshoot the smart entry and start system (for Start Function) after confirming that the communication systems are functioning properly.
Before replacing the certification ECU (smart key ECU assembly), refer to the smart entry and start system (for Entry Function) precaution.
Inspect the fuses of circuits related to this system before performing the following procedure.
After performing repairs, perform the operation that fulfills the DTC output confirmation operation, and then confirm that no DTCs are output again.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G16 certification ECU (smart key ECU assembly) connector.
Disconnect the 2E and 2J instrument panel junction block assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G16-21 (ACCD) - 2E-2 | Always | Below 1 Ω |
| 2J-5 - Body ground | Always | Below 1 Ω |
| G16-21 (ACCD) or 2E-2 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the instrument panel junction block assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Remove the body ECU from the instrument panel junction block assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *a | Component without harness connected (Instrument Panel Junction Block Assembly) | - | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2R-1 - 2P-5 | Battery voltage not applied to terminals 2E-2 and 2J-5 | 10 kΩ or higher |
| Battery voltage applied to terminals 2E-2 and 2J-5 | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2A-1 - 2P-5 | Battery voltage not applied to terminals 2E-2 and 2J-5 | 10 kΩ or higher |
| Battery voltage applied to terminals 2E-2 and 2J-5 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU(for RHD)>REMOVAL
Connect the G16 certification ECU (smart key ECU assembly) connector.
Install the instrument panel junction block assembly.
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected (Certification ECU (Smart Key ECU Assembly)) | - | - |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G16-21 (ACCD) - Body ground | Engine switch off → Engine switch on (ACC) | 1 V or less → 8.5 V or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG