Home › Engine / Hybrid System › 2KD-FTV INTAKE / EXHAUST › EXHAUST MANIFOLD W/ TURBOCHARGER › from 2016.01
RM3270E _51 Engine / Hybrid System _048934 2KD-FTV INTAKE / EXHAUST _0244727 EXHAUST MANIFOLD W/ TURBOCHARGER G

2KD-FTV INTAKE / EXHAUST  EXHAUST MANIFOLD W/ TURBOCHARGER  INSPECTION  


PROCEDURE

Hide 17201 1.VISUALLY CHECK TURBOCHARGER SUB-ASSEMBLY

a.
A230524C03
1.844,1.25 1.969,0.302 1.969,0.302 2.167,0.302 true 2.188,0.208 2.375,0.385 0.188,0.177 10 false *1
*1 Turbine Wheel


Check for deformation and cracks in the turbine wheel on the exhaust side.

If the turbine wheel is cracked or deformed, replace the turbocharger sub-assembly.


Hide 17201 2.INSPECT AXIAL PLAY OF TURBINE SHAFT

a.
A254007

Using a dial indicator, insert the needle of the dial indicator into the exhaust side of the turbine shaft.

NOTICE:

Turbocharger sub-assembly and dial indicators are surely fixed when performing measurement.



b.

Move the turbine shaft in an axial direction and measure the axial play of the turbine shaft.

Maximum axial play:

0.08 mm (0.00314 in.)


If the axial play is more than the maximum, replace the turbocharger sub-assembly.


Hide 17201 3.INSPECT RADIAL PLAY OF TURBINE SHAFT

a.
A254008

Insert the needle of a dial indicator into the oil outlet hole and set it against the center of the turbine shaft.


b.

Move the turbine shaft in the radial direction and measure the radial play of the turbine shaft using the dial indicator.

Maximum radial play:

0.110 mm (0.00433 in.)


If the radial play is more than the maximum, replace the turbocharger sub-assembly.


Hide 17201 4.CHECK TURBINE SHAFT ROTATION

a.
A110325

Rotate the turbine wheel on the exhaust side with your finger and check that it rotates smoothly.

HINT:

Even if it takes a little effort to rotate the turbine wheel, this is not a problem.


If the turbine wheel does not rotate smoothly, replace the turbocharger sub-assembly.


Hide 17230A 5.INSPECT ACTUATOR AND WASTE GATE VALVE OPERATION

a.

Disconnect the actuator hose from the compressor housing.


b.
A346627E01
1.583,0.323 1.854,0.323 1.854,0.323 2.219,0.979 false 1.271,0.219 1.729,0.417 0.458,0.198 10 false SST

Using SST, apply pressure to the actuator.

SST
09992-00242  

Valve opening pressure:

Specified pressure* (See table below)


NOTICE:

Never apply more than the predetermined maximum pressure* to the actuator.


HINT:

*: For the specifications, refer to the table below.


Specifications:
Valve Opening Pressure
(kPa: Gauge Pressure)
Maximum Pressure
(kPa: Gauge Pressure)
Rod Stroke
(Reference)
108 136 2.0 to 4.50 mm
(0.0787 to 0.177 in.)



c.

Check that the actuator push rod moves and that the waste gate valve opens.

If the rod does not move, replace the turbocharger sub-assembly.


d.

Reconnect the actuator hose to the compressor housing.