25861
1.INSTALL VACUUM SWITCHING VALVE BRACKET (for LHD)
Install the vacuum switching valve bracket with the 2 nuts.
25860
2.INSTALL NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (for LHD)
Install the No. 1 vacuum switching valve assembly with the nut.
Connect the No. 1 air hose and No. 2 air hose to the No. 1 vacuum switching valve and slide the 2 clips to secure them.
Connect the connector.
25860
3.INSTALL NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (for RHD)
Install the No. 1 vacuum switching valve assembly with the nut.
44763
4.INSTALL BOOSTER VACUUM TUBE (for RHD)
Install the booster vacuum tube with the 3 nuts.
Connect the No. 1 air hose and No. 2 air hose to the No. 1 vacuum switching valve and slide the 2 clips to secure them.
Connect the check valve to brake booster hose and union to connector tube hose and slide the 2 clips to secure them.
Connect the connector and attach the wire harness clamp.