Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) › from 2016.01
RM3270E _58 Vehicle Interior _041713 HEATING / AIR CONDITIONING _0205064 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) J

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  Rear Blower Motor Circuit  


DESCRIPTION

The cooling unit with fan motor sub-assembly is operated by signals from the air conditioning amplifier. Rear blower motor speed signals are transmitted in accordance with changes in the duty ratio.

WIRING DIAGRAM

E316645E06
5.833,0.75 6.448,0.948 0.615,0.198 10 false RCRL 5.552,0.75 6.167,0.948 0.615,0.198 10 false 23 4.188,0.854 4.802,1.052 0.615,0.198 10 false SI 4.469,0.75 5.083,0.948 0.615,0.198 10 false 3 4.135,1.302 4.75,1.5 0.615,0.198 10 false VM 4.469,1.156 5.083,1.354 0.615,0.198 10 false 2 3.094,0.854 3.708,1.052 0.615,0.198 10 false +B 2.865,0.75 3.479,0.948 0.615,0.198 10 false 1 3.094,1.281 3.708,1.479 0.615,0.198 10 false GND 2.875,1.167 3.49,1.365 0.615,0.198 10 false 6 0.75,0.833 2.052,1.063 1.302,0.229 10 false from Battery 2.083,1 2.698,1.198 0.615,0.198 10 false CLR RR 2.698,1.719 3.313,1.917 0.615,0.198 10 false N35 2.698,1.885 5.031,2.156 2.333,0.271 10 false Air Conditioning Control Assembly 4.479,2.375 5.094,2.573 0.615,0.198 10 false 2 2.854,2.385 3.469,2.583 0.615,0.198 10 false 1 3.073,2.833 3.688,3.031 0.615,0.198 10 false N31 3.073,3 4.406,3.375 1.333,0.375 10 false Rear Blower with Fan Motor Sub-assembly 5.521,1.625 6.135,1.823 0.615,0.198 10 false G37 5.531,1.792 7.115,2.219 1.583,0.427 10 false Air Conditioning Amplifier Assembly 4.26,2.375 4.875,2.573 0.615,0.198 10 false B 3.063,2.375 3.677,2.573 0.615,0.198 10 false L

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

·

When the servo motor or air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)>INITIALIZATION



PROCEDURE

1.PERFORM ACTIVE TEST USING GTS (BLOWER MOTOR)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower with fan motor sub-assembly Min.: 0
Max.: 31
-
Body Electrical > Air Conditioner > Active Test
Tester Display
Blower Motor
50004 121 2
OK:

Blower with fan motor sub-assembly operates and changes speed.



Result:
Proceed to
OK
NG



OK

NG

2.INSPECT REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY
2.INSPECT REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY
a.

Remove the rear blower with fan motor sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REAR BLOWER MOTOR>REMOVAL


b.

Inspect the rear blower with fan motor sub-assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REAR BLOWER MOTOR>INSPECTION


Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BATTERY AND BODY GROUND)

NG

REPLACE REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BATTERY AND BODY GROUND)
a.
E293155C05
1.448,0.167 1.969,0.417 0.521,0.25 2.583,1.833 2.333,1.833 2.333,1.833 2.083,1.583 true 0.75,0.917 1,0.917 1,0.917 1.344,1.24 true 1.594,0.219 2.052,0.417 0.458,0.198 10 false N35 0.073,0.073 0.531,0.271 0.458,0.198 10 false *a 0.542,0.833 1,1.031 0.458,0.198 10 false +B 2.625,1.74 3.083,1.938 0.458,0.198 10 false GND
*a Front view of wire harness connector
(to Air Conditioning Control Assembly)


Disconnect the air conditioning control assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
N35-6 (GND) - Body ground Always Below 1 Ω



c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
N35-1 (+B) - Body ground Always 11 to 14 V



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the N35 air conditioning control assembly connector.


b.

Disconnect the G37 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
N35-3 (SI) - G37-23 (RCRL) Always Below 1 Ω
N35-3 (SI) or G37-23 (RCRL) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.CHECK HARNESS AND CONNECTOR (REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY - AIR CONDITIONING CONTROL ASSEMBLY AND BODY GROUND)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY - AIR CONDITIONING CONTROL ASSEMBLY AND BODY GROUND)
a.

Disconnect the N31 rear blower with fan motor sub-assembly connector.


b.

Disconnect the N35 air conditioning control assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
N31-2 (B) - N35-2 (VM) Always Below 1 Ω
N31-1 (L) - Body ground Always Below 1 Ω
N31-2 (B) or N35-2 (VM) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

6.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
a.
E313780C04
0.49,0.604 1.021,0.896 0.531,0.292 2.333,1.333 2.083,1.333 2.083,1.333 1.958,1.063 true 0.063,0.083 0.375,0.281 0.313,0.198 10 false *a 2.375,1.26 2.688,1.458 0.313,0.198 10 false SI 2.875,2.667 3.323,2.906 0.448,0.24 10 false GND 0.635,0.667 0.948,0.865 0.313,0.198 10 false N35
*a Component with harness connected
(Air Conditioning Control Assembly)


Using an oscilloscope, check the waveform.

Item Content
Terminal No. (Symbol) N35-3 (SI) - Body ground
Tool Setting 2 V/DIV., 500 μs/DIV.
Condition
·

Ignition switch ON

·

Blower switch: LO



OK:

Waveform is as shown in the illustration.


HINT:

Waveform varies with the blower level.



Result:
Proceed to
OK
NG



OK

NG

7.CHECK AIR CONDITIONING CONTROL ASSEMBLY
7.CHECK AIR CONDITIONING CONTROL ASSEMBLY
a.

b.

Check if the same malfunction recurs when the sonar function is operated.

OK:

Malfunction does not reoccur (returns to normal).



Result:
Proceed to
OK
NG



OK

END (AIR CONDITIONING CONTROL ASSEMBLY IS DEFECTIVE)

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY