Home › Vehicle Interior › SEAT › POWER SEAT SWITCH › from 2016.01
RM3270E _58 Vehicle Interior _041711 SEAT _0203012 POWER SEAT SWITCH G

SEAT  POWER SEAT SWITCH  INSPECTION  


PROCEDURE

Hide 84922B 1.INSPECT FRONT POWER SEAT SWITCH RH (for RHD)

a.
B444912C01
2.281,1.365 2.229,0.604 true 1.917,1.375 1.615,0.604 true 1.219,1.115 0.771,0.563 true 3.063,1.375 2.656,1.375 true 2.583,3.167 2.177,3.167 true 2.479,2.656 2.01,3.104 true 2.031,2.677 1.885,3.104 true 1.313,2.677 1.5,3.115 true 0.885,2.667 1.365,3.115 true 1.198,3.177 0.792,3.177 true 1.781,3.375 2.167,3.719 true 1.656,3.375 1.76,3.729 true 1.521,3.375 1.333,3.76 true 1.375,3.375 0.865,3.781 true 2.167,0.385 2.479,0.542 0.313,0.156 10 false *1 3.125,1.271 3.344,1.427 0.219,0.156 10 false *2 1.531,0.385 1.844,0.542 0.313,0.156 10 false *3 0.552,0.385 0.865,0.542 0.313,0.156 10 false *4 0.198,2.354 0.51,2.51 0.313,0.156 10 false *a 0.698,2.479 1.115,2.667 0.417,0.188 10 false SLDR 1.167,2.479 1.583,2.667 0.417,0.188 10 false LUP 2.365,2.479 2.781,2.667 0.417,0.188 10 false SLDF 1.854,2.479 2.271,2.667 0.417,0.188 10 false LDWN 2.656,3.073 3.219,3.271 0.563,0.198 10 false FDWN 0.427,3.115 0.844,3.302 0.417,0.188 10 false FUP 0.76,3.792 1.177,3.979 0.417,0.188 10 false B 1.156,3.771 1.573,3.958 0.417,0.188 10 false RCLR 1.625,3.771 2.042,3.958 0.417,0.188 10 false RCLF 2.167,3.76 2.583,3.948 0.417,0.188 10 false E
*1 Slide Switch
*2 Front Vertical Switch
*3 Lifter Switch
*4 Reclining Switch
*a Component without harness connected
(Front Power Seat Switch RH)


Measure the resistance according to the value (s) in the tables below.

Standard Resistance (Slide Switch):
Tester Connection Switch Condition Specified Condition
2 (SLDF) - 13 (B) Front position Below 1 Ω
5 (SLDR) - 10 (E)
2 (SLDF) - 10 (E) Neutral Below 1 Ω
5 (SLDR) - 10 (E)
2 (SLDF) - 10 (E) Rear position Below 1 Ω
5 (SLDR) - 13 (B)

Standard Resistance (Front Vertical Switch):
Tester Connection Switch Condition Specified Condition
6 (FUP) - 13 (B) Up position Below 1 Ω
1 (FDWN) - 10 (E)
6 (FUP) - 10 (E) Neutral Below 1 Ω
1 (FDWN) - 10 (E)
6 (FUP) - 10 (E) Down position Below 1 Ω
1 (FDWN) - 13 (B)

Standard Resistance (Lifter Switch):
Tester Connection Switch Condition Specified Condition
4 (LUP) - 13 (B) Up position Below 1 Ω
3 (LDWN) - 10 (E)
4 (LUP) - 10 (E) Neutral Below 1 Ω
3 (LDWN) - 10 (E)
4 (LUP) - 10 (E) Down position Below 1 Ω
3 (LDWN) - 13 (B)

Standard Resistance (Reclining Switch):
Tester Connection Switch Condition Specified Condition
11 (RCLF) - 13 (B) Front position Below 1 Ω
12 (RCLR) - 10 (E)
6 (FUP) - 13 (B)
1 (FDWN) - 13 (B)
11 (RCLF) - 10 (E) Neutral Below 1 Ω
12 (RCLR) - 10 (E)
11 (RCLF) - 10 (E) Rear position Below 1 Ω
12 (RCLR) - 13 (B)
3 (LDWN) - 13 (B)
4 (LUP) - 13 (B)

If the result is not as specified, replace the front power seat switch RH.


Hide 84922C 2.INSTALL FRONT POWER SEAT SWITCH LH (for LHD)

a.
B239569C17
1.875,3.115 1.99,2.615 true 2.031,3.125 2.448,2.708 true 2.094,3.896 1.875,3.396 true 2.323,1.104 2.813,0.615 true 1.521,3.115 1.385,2.604 true 1.375,3.896 1.615,3.385 true 1.281,1.344 0.969,0.396 true 0.427,1.365 0.917,1.365 true 1.219,3.167 0.865,3.167 true 1.385,3.115 1.073,2.75 true 1.729,3.885 1.76,3.385 true 1.646,1.354 2.063,0.385 true 2.156,3.167 2.542,3.167 true 2.021,3.396 2.552,3.885 true 0.844,0.219 1.156,0.375 0.313,0.156 10 false *1 0.26,1.292 0.573,1.448 0.313,0.156 10 false *2 2.031,0.219 2.344,0.375 0.313,0.156 10 false *3 2.833,0.458 3.146,0.615 0.313,0.156 10 false *4 0.323,2.313 0.635,2.469 0.313,0.156 10 false *a 2.635,3.094 3.25,3.292 0.615,0.198 10 false FUP 2.365,2.51 2.979,2.708 0.615,0.198 10 false SLDR 1.896,2.406 2.51,2.604 0.615,0.198 10 false LUP 1.167,2.406 1.625,2.604 0.458,0.198 10 false LDWN 0.688,2.656 1.302,2.854 0.615,0.198 10 false SLDF 0.427,3.083 0.885,3.281 0.458,0.198 10 false FDWN 1.302,3.927 1.458,4.125 0.156,0.198 10 false E 1.552,3.927 2.167,4.125 0.615,0.198 10 false RCLF 2,3.927 2.615,4.125 0.615,0.198 10 false RCLR 2.563,3.938 2.719,4.135 0.156,0.198 10 false B
*1 Slide Switch
*2 Front Vertical Switch
*3 Lifter Switch
*4 Reclining Switch
*a Component without harness connected
(Front Power Seat Switch LH)


Measure the resistance according to the value (s) in the tables below.

Standard Resistance (Slide Switch):
Tester Connection Switch Condition Specified Condition
5 (SLDF) - 8 (B) Front position Below 1 Ω
2 (SLDR) - 11 (E)
5 (SLDF) - 11 (E) Neutral Below 1 Ω
2 (SLDR) - 11 (E)
5 (SLDF) - 11 (E) Rear position Below 1 Ω
2 (SLDR) - 8 (B)

Standard Resistance (Front Vertical Switch):
Tester Connection Switch Condition Specified Condition
1 (FUP) - 8 (B) Up position Below 1 Ω
6 (FDWN) - 11 (E)
1 (FUP) - 11 (E) Neutral Below 1 Ω
6 (FDWN) - 11 (E)
1 (FUP) - 11 (E) Down position Below 1 Ω
6 (FDWN) - 8 (B)

Standard Resistance (Lifter Switch):
Tester Connection Switch Condition Specified Condition
3 (LUP) - 8 (B) Up position Below 1 Ω
4 (LDWN) - 11 (E)
3 (LUP) - 11 (E) Neutral Below 1 Ω
4 (LDWN) - 11 (E)
3 (LUP) - 11 (E) Down position Below 1 Ω
4 (LDWN) - 8 (B)

Standard Resistance (Reclining Switch):
Tester Connection Switch Condition Specified Condition
10 (RCLF) - 8 (B) Front position Below 1 Ω
9 (RCLR) - 11 (E)
1 (FUP) - 8 (B)
6 (FDWN) - 8 (B)
10 (RCLF) - 11 (E) Neutral Below 1 Ω
9 (RCLR) - 11 (E)
10 (RCLF) - 11 (E) Rear position Below 1 Ω
9 (RCLR) - 8 (B)
4 (LDWN) - 8 (B)
3 (LUP) - 8 (B)

If the result is not as specified, replace the front power seat switch LH.