RM3270E
_V1
General
_041724
SPECIFICATIONS
_0254118
2GD-FTV EMISSION CONTROL
F
SPECIFICATIONS 2GD-FTV EMISSION CONTROL SERVICE DATA
NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
33 to 39 Ω
|
1 - Body ground
2 - Body ground
|
20°C (68°F)
|
1 MΩ or higher
|