Home › Engine / Hybrid System › 2TR-FE ENGINE CONTROL › SFI SYSTEM
RM1880E _51 Engine / Hybrid System _013209 2TR-FE ENGINE CONTROL _0068463 SFI SYSTEM U

2TR-FE ENGINE CONTROL  SFI SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


HINT:

Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:
·

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

·

The actual values may differ from the values listed in the chart under "Results of real-vehicle check" due to climate, weather conditions, etc.



HINT:

Normal Condition: If no conditions are specifically stated for "idling", the shift lever should be in N or P, the A/C should be off and all accessory switches should be off.


a.

Warm up the engine.


b.

Turn the A/C off.


c.

Turn the ignition switch off.


d.

Connect the intelligent tester to the DLC3.


e.

Turn the ignition switch to ON.


f.

Turn the intelligent tester on.


g.

Enter the following menus: Powertrain / Engine and ECT / Data List.

HINT:
·

To display the list box, press the pull down menu button next to Primary. Then select a measurement group.

·

When you select a measurement group, the ECU data belonging to that group is displayed.

·

Measurement Group List / Description

·

All Data / All data

·

Primary / -

·

Engine Control / Engine control system related data

·

Ptrl General / -

·

Ptrl AF Control / Air fuel ratio control system related data

·

Ptrl AF O2 Sensor / Air fuel ratio sensor and heated oxygen sensor related data

·

Ptrl Throttle / Gasoline throttle system related data

·

Ptrl Intake Control / Intake control system related data

·

Ptrl Valve Control / Valve control system related data

·

Ptrl Misfire / "Misfire" related data

·

Ptrl Starting / "Difficult to start" related data

·

Ptrl Rough Idle / "Rough idle" related data

·

Ptrl Evaporative / Evaporative system related data

·

Ptrl 2nd Air / Secondary air injection system related data

·

Ptrl CAT Converter / Catalyst converter related data

·

Check Mode / Check mode related data

·

Monitor Status / Monitor status related data

·

Ignition / Ignition system related data

·

Charging Control / Charging control system related data

·

Compression / Data used during "Check the Cylinder Compression" Active Test

·

AT / Automatic transmission system related data

·

Vehicle Information / Vehicle information





h.

According to the display on the intelligent tester, read the Data List.

HINT:

The title used for each group of Data List items in this repair manual does not appear on the intelligent tester. However, the name in parentheses after the title, which is a Measurement Group, does appear on the intelligent tester. When the name shown in parentheses is selected on the intelligent tester, all the Data List items listed for that group will be displayed.




Various Vehicle Conditions 1 (All Data)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Vehicle Speed Vehicle speed Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) Actual vehicle speed
·

This is the current vehicle speed.

·

The vehicle speed is detected using the speed sensors.

·

Vehicle speed data is delayed when it is displayed. Therefore, even if the vehicle speed listed in the freeze frame data is 0 km/h (0 mph), this does not always mean that the malfunction occurred when the vehicle was stopped.



Stored as Freeze Frame Data

Yes


Engine Speed Engine speed Min.: 0 rpm, Max.: 16383 rpm 600 to 700 rpm: Idling When the crankshaft position sensor is malfunctioning, "Engine Speed" is approximately 0 or varies greatly from the actual engine speed.
Stored as Freeze Frame Data

Yes


Calculate Load Load calculated by ECM Min.: 0%, Max.: 100% - This is the engine load calculated based on the estimated intake manifold pressure.
Calculate Load = Estimated intake manifold pressure / maximum intake manifold pressure x 100 (%)
(For example, when the estimated intake manifold pressure is the same as atmospheric pressure, Calculate Load is 100%.)
Stored as Freeze Frame Data

Yes


MAF Airflow rate from Mass Air Flow (MAF) meter Min.: 0 gm/s, Max.: 655.35 gm/s 1.0 to 4.0 gm/s: Idling
4.0 to 15.0 gm/s: 2500 rpm (without load)
This is the intake air amount from the mass air flow meter.
Stored as Freeze Frame Data

Yes


Atmosphere Pressure Atmospheric pressure Min.: 0 kPa, Max.: 255 kPa Equivalent to atmospheric pressure (absolute pressure)
·

This value is calculated from the intake air amount.

·

Standard atmospheric pressure: 101 kPa

·

For every 100 m increase in altitude, pressure drops by 1 kPa. This varies by weather.


Stored as Freeze Frame Data

Yes


Coolant Temp Coolant temperature Min.: -40°C, Max.: 140°C 80 to 95°C (176 to 203°F): After warming up This is the engine coolant temperature.
HINT:
·

After warming up the engine, the engine coolant temperature is 75 to 100°C .

·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature are approximately equal.

·

If the value is -40°C (-40°F) or 140°C (284°F), the sensor circuit is open or shorted.



Stored as Freeze Frame Data

Yes


Intake Air Intake air temperature Min.: -40°C, Max.: 140°C Equivalent to temperature at location of mass air flow meter
·

After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature are approximately equal.

·

If the value is -40°C (-40°F) or 140°C (284°F), the sensor circuit is open or shorted.


Stored as Freeze Frame Data

Yes


Engine Run Time Engine run time Min.: 0 s, Max.: 65535 s Time after engine start This is the time elapsed since the engine started.
HINT:

The time is counted only while the engine is running.


Stored as Freeze Frame Data

Yes


Initial Engine Coolant Temp Initial engine coolant temperature Min.: -40°C, Max.: 215°C - This is the coolant temperature stored when the ignition switch is turned to ON.
Stored as Freeze Frame Data

Yes


Initial Intake Air Temp Initial intake air temperature Min.: -40°C, Max.: 140°C - This is the intake air temperature stored when the ignition switch is turned to ON.
Stored as Freeze Frame Data

Yes


Battery Voltage Battery voltage Min.: 0 V, Max.: 65.535 V 11 to 14 V: Idling If 11 V or less, characteristics of some electrical components may change.
Stored as Freeze Frame Data

Yes



Throttle Control (Ptrl Throttle)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Accel Sens. No.1 Volt % Absolute Accelerator Pedal Position (APP) No. 1 Min.: 0%, Max.: 100% 10 to 22%: Accelerator pedal released
54 to 86%: Accelerator pedal fully depressed
The accelerator pedal position sensor No. 1 output is converted using 5 V = 100%.
HINT:

If there are no accelerator pedal position sensor DTCs stored, it is possible to conclude that the accelerator pedal position sensor system is normal.


Stored as Freeze Frame Data

Yes


Accel Sens. No.2 Volt % Absolute APP No. 2 Min.: 0%, Max.: 100% 12 to 42%: Accelerator pedal released
66 to 98%: Accelerator pedal fully depressed
The accelerator pedal position sensor No. 2 output is converted using 5 V = 100%.
Stored as Freeze Frame Data

Yes


Accel Sensor Out No.1 APP sensor No. 1 voltage Min.: 0 V, Max.: 4.98 V 0.5 to 1.1 V: Accelerator pedal released
2.6 to 4.5 V: Accelerator pedal fully depressed
This is the raw voltage from the accelerator pedal position sensor No. 1.
Stored as Freeze Frame Data

No


Accel Sensor Out No.2 APP sensor No. 2 voltage Min.: 0 V, Max.: 4.98 V 1.2 to 2.0 V: Accelerator pedal released
3.4 to 4.98 V: Accelerator pedal fully depressed
This is the raw voltage from the accelerator pedal position sensor No. 2.
Accelerator pedal position sensor No. 2 is used to monitor accelerator pedal position sensor No. 1. When there is a malfunction in sensor No. 1, the ECM uses sensor No. 2 to control the engine.
Stored as Freeze Frame Data

No


Accelerator Idle Position Whether or not accelerator pedal position sensor detecting released accelerator pedal ON or OFF ON: Accelerator pedal released This is a parameter calculated by the ECM which indicates whether the accelerator pedal is in the learned idle position.
Stored as Freeze Frame Data

No


Accel Fully Close #1 (AD) Accelerator fully closed value No. 1 (AD) Min.: 0 V, Max.: 4.9 V -
Stored as Freeze Frame Data

No


Accel Fully Close Learn #1 Accelerator fully released learned value No. 1 Min.: 0 deg, Max.: 124.5 deg - This is the value of accelerator pedal position sensor No. 1 learned when the accelerator pedal is released.
Stored as Freeze Frame Data

No


Accel Fully Close Learn #2 Accelerator fully released learned value No. 2 Min.: 0 deg, Max.: 124.5 deg - This is the value of accelerator pedal position sensor No. 2 learned when the accelerator pedal is released.
Stored as Freeze Frame Data

No


Throttle Sensor Volt % Absolute throttle position sensor Min.: 0%, Max.: 100%
·

10 to 22%: Throttle fully closed

·

66 to 98%: Throttle fully open


The throttle position sensor No. 1 output is converted using 5 V = 100%.
HINT:

If there are no throttle position sensor DTCs stored, it is possible to conclude that the throttle position sensor system is normal.


Stored as Freeze Frame Data

Yes


Throttl Sensor #2 Volt % Throttle sensor position #2 Min.: 0%, Max.: 100%
·

42 to 62%: Throttle fully closed

·

92 to 100%: Throttle fully open


The throttle position sensor No. 2 output is converted using 5 V = 100%.
Stored as Freeze Frame Data

Yes


ST1 Brake pedal signal ON or OFF ON: Brake pedal depressed
OFF: Brake pedal released
This is the stop light switch signal.
Stored as Freeze Frame Data

No


System Guard System guard ON or OFF ON When there is a difference between the target and actual throttle valve opening angles, system guard turns off and stops the electronic throttle control system function.
OFF: Electronic throttle control is stopped.
Stored as Freeze Frame Data

No


Open Side Malfunction Open malfunction ON or OFF OFF This parameter indicates a malfunction in the electronic throttle when the throttle valve is open.
Stored as Freeze Frame Data

No


Throttle Idle Position Whether or not throttle position sensor detecting idle ON or OFF - This is a parameter calculated by the ECM.
The value is ON when the throttle is at the idle position and OFF when the throttle is open.
Stored as Freeze Frame Data

No


Throttle Require Position Required throttle position Min.: 0 V, Max.: 4.98 V - This is a value calculated by the ECM showing the voltage for the target throttle valve position. It is almost an exact match of the Throttle Position No. 1 value except during very rapid throttle valve movement, such as that used during wheelspin control.
Stored as Freeze Frame Data

No


Throttle Sensor Position Throttle sensor position Min.: 0%, Max.: 100%
·

0%: Throttle fully closed

·

50 to 80%: Throttle fully open


This is the throttle valve opening amount used for engine control.
(100% signifies 125° of throttle valve rotation. This does not include the amount the throttle valve is opened to maintain the idling speed during idling.)
This value has no meaning when the ignition switch is ON and the engine is stopped.
The throttle valve opening amount during idling is indicated by 0%. When the throttle valve is fully open, the value is 68%.
Stored as Freeze Frame Data

Yes


Throttle Position No.1 Throttle position sensor No. 1 output voltage Min.: 0 V, Max.: 4.98 V Almost same as "Throttle Require Position"
·

0.5 to 1.1 V: Throttle fully closed

·

3.2 to 4.8 V: Throttle fully open

·

0.6 to 1.4 V: Fail-safe operating


This is the throttle position sensor No. 1 output voltage.
Stored as Freeze Frame Data

No


Throttle Position No.2 Throttle position sensor No. 2 output voltage Min.: 0 V, Max.: 4.98 V
·

2.1 to 3.1 V: Throttle fully closed

·

4.6 to 4.98 V: Throttle fully open

·

2.1 to 3.1 V: Fail-safe operating


This is the throttle position sensor No. 2 output voltage.
Stored as Freeze Frame Data

No


Throttle Position Command Throttle position command value Min.: 0 V, Max.: 4.98 V - Throttle Position Command is the same value as Throttle Require Position.
Stored as Freeze Frame Data

No


Throttle Sens Open Pos #1 Throttle position sensor No. 1 Min.: 0 V, Max.: 4.98 V 0.6 to 0.9 V This is the throttle position sensor No. 1 output voltage when there is no current supplied to the electronic throttle actuator. The accelerator pedal is released but the throttle valve is kept open by the throttle valve opener with the ignition switch ON.
Stored as Freeze Frame Data

No


Throttle Sens Open Pos #2 Throttle position sensor No. 2 Min.: 0 V, Max.: 4.98 V 2.2 to 2.6 V This is the throttle position sensor No. 2 output voltage when there is no current supplied to the electronic throttle actuator. The accelerator pedal is released but the throttle valve is kept open by the throttle valve opener with the ignition switch ON.
Stored as Freeze Frame Data

No


Throttle Sens Open #1(AD) Throttle sensor opener position No. 1 (AD) Min.: 0 V, Max.: 4.9 V 0.6 to 0.9 V
Stored as Freeze Frame Data

No


Throttle Motor Whether or not throttle motor control is permitted ON or OFF Idling: ON Read the value with the ignition switch ON (Do not start engine)
Stored as Freeze Frame Data

No


Throttle Motor Current Throttle actuator current Min.: 0 A, Max.: 19.9 A 0 to 3.0 A: Idling
·

When this value is large but the actual opening angle (Throttle Position No. 1) does not reach the target opening angle (Throttle Require Position), there is an "unable to open" malfunction.

·

This value normally fluctuates around 1 A.


Stored as Freeze Frame Data

No


Throttle Motor DUTY Throttle actuator Min.: 0%, Max.: 100% 10 to 22%: Idling This is the output duty ratio of the throttle actuator drive circuit.
Stored as Freeze Frame Data

Yes


Throttle Motor Duty (Open) Throttle actuator duty ratio (open) Min.: 0%, Max.: 255% 0 to 40%: Idling
·

This is the duty ratio used to drive the throttle actuator and open the throttle valve. It is an ECM command signal.

·

When the throttle valve is being opened, Throttle Motor Duty (Open) is 20 to 30%.


Stored as Freeze Frame Data

No


Throttle Motor Duty (Close) Throttle actuator duty ratio (close) Min.: 0%, Max.: 255% 0 to 40%: Idling This is the duty ratio used to drive the throttle actuator and close the throttle valve. It is an ECM command signal.
HINT:

During idling, the throttle valve opening angle is usually controlled using a duty ratio drive signal which closes the throttle valve. However, when carbon deposits build up, it may be necessary to open the throttle valve more than the throttle valve opener does. In that case, the opening angle is controlled using a "Throttle Motor Duty (Open)" signal which opens the throttle valve.


Stored as Freeze Frame Data

No


Throttle Fully Close Learn Throttle valve fully closed position (learned value) Min.: 0 V, Max.: 4.98 V 0.4 to 1.0 V: Accelerator pedal released
·

The ECM uses this learned value to determine the fully closed (and fully open) position of the throttle valve. This learned value is calculated by the ECM with the throttle valve opener angle (approximately 4 to 7°, the position when the ignition switch is ON, the accelerator pedal is released and the throttle actuator is off).

·

Learning is performed immediately after the ignition switch is turned to ON.


Stored as Freeze Frame Data

No


ETCS Actuator Power Whether or not electric throttle control system power is input ON or OFF Idling: ON
Stored as Freeze Frame Data

No


+BM Voltage +BM voltage Min.: 0 V, Max.: 79.998 V 11 to 14 V: Ignition switch ON and system normal This is the power supply for the electronic throttle actuator. When the power supply is interrupted for approximately 1 second, DTCs P2118 (open circuit) and P0657 (short circuit, ECU malfunction) are stored and the electronic throttle control system enters fail-safe mode (normal operation is not restored until the ignition switch is turned off).
Stored as Freeze Frame Data

No


Actuator Power Supply Actuator power supply ON or OFF ON: Idling If +BM power is lost, this item changes to OFF.
Stored as Freeze Frame Data

No


Fail Safe Drive Whether or not fail-safe function is executed ON or OFF ETCS has failed: ON
Stored as Freeze Frame Data

No


Fail Safe Drive (Main CPU) Whether or not fail-safe function is executed ON or OFF ETCS has failed: ON
Stored as Freeze Frame Data

No



Fuel System (Ptrl General)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Injector (Port) Injection period of the No. 1 cylinder Min.: 0 μs, Max.: 65535 μs - This is the injection period of the No. 1 cylinder (the command value from the ECM).
Stored as Freeze Frame Data

Yes


Injection Volum (Cylinder1) Injection volume (cylinder 1) Min.: 0 ml, Max.: 2.047 ml 0 to 0.5 ml This is the fuel injection volume for 10 injections.
Stored as Freeze Frame Data

Yes


Fuel Pump/Speed Status Fuel pump status ON or OFF ON: Starter on or engine running
Stored as Freeze Frame Data

Yes



EVAP System (Ptrl Evaporative)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Evap Purge Flow Purge flow Min.: 0%, Max.: 399.9% - This is the percentage of total engine airflow contributed by EVAP purge operation.
(Evap Purge Flow = Purge flow / Engine airflow x 100 (%))
It is based on MAF and a stored value for airflow and controlled by adjusting the duty cycle for the purge VSV.
Stored as Freeze Frame Data

Yes


Purge Density Learn Value Purge density learned value Min.: -200, Max.: 199.993 - Purge Density Learn Value is the proportion of the decrease in injection volume (based on the change in the air-fuel ratio feedback compensation value) related to a 1% purge flow rate.
When Purge Density Learn Value is a large negative value, the purge effect is large.
The purge density is determined from the change in the air-fuel ratio feedback compensation value when purge flow is introduced.
Purge density learning is performed so that the feedback compensation value is 0 +/-2%.
HINT:
·

Usually, the value is approximately +/-1%.

·

1%: The concentration of HC in the purge gas is relatively low.

·

0%: The concentration of HC in the purge gas is approximately equal to the stoichiometric air-fuel ratio.

·

Large negative values indicate that the concentration of HC in the purge gas is relatively high.



Stored as Freeze Frame Data

Yes


EVAP Purge VSV VSV status for EVAP control ON or OFF - This parameter displays ON when the VSV duty ratio is 30% or more, and displays OFF when the VSV duty ratio is less than 30%.
Stored as Freeze Frame Data

Yes



Air Fuel Ratio Control 1 (All Data)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Target Air-Fuel Ratio Target air fuel ratio Min.: 0, Max.: 1.99 0.8 to 1.2: During idling This is the target air-fuel ratio used by the ECM.

1.0 is the stoichiometric air-fuel ratio. Values that are more than 1 indicate the system attempting to make the air-fuel ratio leaner. Values that are less than 1 indicate the system attempting to make the air-fuel ratio richer.


Stored as Freeze Frame Data

Yes



Air Fuel Ratio Control 2 (Ptrl AF O2 Sensor)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
O2S B1S1 Heated oxygen sensor output voltage for Bank 1 Sensor 1 Min.: 0 V, Max.: 1.275 V 0 to 1 V This is the output voltage of the heated oxygen sensor.

Values close to 0 V indicate an air-fuel ratio leaner than the stoichiometric ratio.

Values close to 1 V indicate an air-fuel ratio richer than the stoichiometric ratio.

During air-fuel ratio feedback control, the value moves back and forth in the range of 0 to 1 V.


Performing the "Control the Injection Volume" or "Control the Injection Volume for A/F Sensor" function of the Active Test enables the technician to check voltage output of the sensor.
Results of real-vehicle check when performing the Active Test:
Injection Volume: -12.5%
·

O2S B1S1: 0.06 V


Injection Volume: +12.5%
·

O2S B1S1: 0.94 V


Stored as Freeze Frame Data

Yes


Short FT #1 Short-term fuel trim for bank 1 Min.: -100%, Max.: 99.2% -20 to 20% This item is the "short-term fuel injection volume compensation ratio" used to maintain the air fuel ratio at the stoichiometric ratio using the heated oxygen sensor for feedback.
Stored as Freeze Frame Data

Yes


Long FT #1 Long-term fuel trim for bank 1 Min.: -100%, Max.: 99.2% -20 to 20% The ECM will learn the Long FT values based on Short FT. The goal is to keep Short FT at 0% to keep the A/F mixture at the stoichiometric ratio.
This value is used to determine whether the air-fuel ratio control system is malfunctioning.
The condition of the system is determined based on the sum of Short FT and Long FT (excluding times when the system is in transition).
·

+15% or more: The air-fuel ratio may be lean.

·

-15 to +15%: The air-fuel ratio can be determined to be normal.

·

-15% or less: The air-fuel ratio may be rich.


The learned value is cleared when the battery cable is disconnected.
Stored as Freeze Frame Data

Yes


Fuel System Status #1 Fuel system status for bank 1 OL, CL, OL Drive, OL Fault or CL Fault CL: Idling after warming up
·

OL (Open Loop): Has not yet satisfied conditions to go to closed loop.

·

CL (Closed Loop): Uses feedback to perform fuel control.

·

OL Drive: Open loop due to driving conditions (fuel enrichment).

·

OL Fault: Open loop due to a detected system fault.

·

CL Fault: Closed loop but the heated oxygen sensor, which is used for fuel control, is malfunctioning.


CL (Closed Loop): During air-fuel ratio feedback control, O2S B1S1 is approximately 0.45 V.
Stored as Freeze Frame Data

Yes


O2FT B1S1 Short-term fuel trim associated with bank 1 sensor 1 Min.: -100%, Max.: 99.2% -20 to 20% This item is the "short-term fuel injection volume compensation ratio" used to maintain the air fuel ratio at the stoichiometric ratio using the heated oxygen sensor for feedback.
Stored as Freeze Frame Data

Yes



Ignition System (Ignition)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
IGN Advance Ignition timing advance for No. 1 cylinder Min.: -64 deg., Max.: 63.5 deg. BTDC 0 to 20 deg.: Idling
Stored as Freeze Frame Data

Yes


Knock Feedback Value Knocking feedback value Min.: -1024° CA, Max.: 1023.9° CA - This is the ignition timing retard compensation amount determined by the presence or absence of knocking.
Ignition timing = Most retarded timing value*1 + Knock Correct Learn Value*2 + Knock Feedback Value*3 + each compensation amount
Example: 21°CA = 10° + 14° - 3°
*1: The most retarded timing value is a constant determined by the engine speed and engine load.
*2: The knock correction learned value is calculated as shown below in order to keep Knock Feedback Value as close to -3°CA as possible.
When Knock Feedback Value is less than -4°CA, Knock Correct Learn Value is slowly decreased.
When Knock Feedback Value is more than -2°CA, Knock Correct Learn Value is slowly increased.
*3: The base value is -3°CA and is adjusted based on the presence or absence of knocking. When there is no knocking, the value is increased, and when knocking is present, the value is decreased.

-1°CA: There is no knocking and ignition timing is advanced.

-6°CA: Knocking is present and the ignition timing is being retarded.


HINT:

If Knock Feedback Value does not change around the time when knocking occurs even though knocking continues (for example, stays at -3°CA), it can be determined that knocking is not being detected.

Possible Causes:
·

There is a problem with the knock sensor sensitivity.

·

The knock sensor is improperly installed.

·

There is a problem with a wire harness.



Stored as Freeze Frame Data

Yes


Knock Correct Learn Value Knocking correction learned value Min.: -1024° CA, Max.: 1023.9° CA - Refer to "Knock Feedback Value".
When there is knocking or a lack of power, compare the following values to another vehicle of the same model.
·

Engine speed

·

Calculate Load

·

IGN Advance

·

Knock Feedback Value

·

Knock Correct Learn Value


Knock Correct Learn Value is large: There is no knocking and the ignition timing is advanced.
Knock Correct Learn Value is small: Knocking is present and the ignition timing is being retarded.
HINT:

When knocking continues even though Knock Correct Learn Value is less than that of the vehicle being used for comparison (in other words, the ignition timing is being retarded but the knocking is not stopping), there may be a buildup of deposits or other such problems due to deterioration over time (oil entering the cylinders, poor quality fuel, etc.).


Stored as Freeze Frame Data

Yes



VVT Control (Ptrl Valve Control)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
VVT Control Status #1 Variable Valve Timing (VVT) control status for bank 1 ON or OFF - ON: The ECM is sending commands to change the timing (even when the timing is advanced, when the timing is being maintained and not being retarded or advanced any further, the value changes to OFF).
OFF: The system is commanding the timing to change to the most retarded timing.
Stored as Freeze Frame Data

Yes


VVT Aim Angle #1 VVT hold duty learned value for bank 1 Min.: 0%, Max.: 100% - This value represents the duty ratio necessary to operate the camshaft timing oil control valve in order to block the camshaft timing oil control valve path and maintain the advanced state of the camshaft timing gear. This is only available during the Active Test.
Refer to "VVT OCV Duty #1".
Stored as Freeze Frame Data

No


VVT Change Angle #1 VVT displacement angle for bank 1 Min.: 0 DegFR, Max.: 639.9 DegFR - This is the VVT displacement angle during forced operation.
This is only available during the Active Test.
By checking VVT Change Angle during the Active Test, it is also possible to determine whether or not the camshaft position sensor signal is being output.
Refer to "VVT OCV Duty #1".
Stored as Freeze Frame Data

No


VVT OCV Duty #1 VVT camshaft timing oil control valve operation duty for bank 1 Min.: 0%, Max.: 100% - This is the requested duty value for forced operation.
This is only available during the Active Test.
Results of the real-vehicle check when performing the Control the VVT Linear (Bank 1) Active Test:
VVT OCV Duty #1 = 0%, VVT Change Angle #1 = 0 DegFR
↓
VVT OCV Duty #1 = 30%, VVT Change Angle #1 = 0 DegFR
↓
VVT OCV Duty #1 = 70%, VVT Change Angle #1 = 39.0 DegFR
↓
VVT OCV Duty #1 = 100%, VVT Change Angle #1 = 39.0 DegFR
↓
VVT OCV Duty #1 = 32%, VVT Change Angle #1 = 0 DegFR
After the above test, VVT Aim Angle #1 = 26.6%.
Stored as Freeze Frame Data

No



Various Vehicle Conditions 2 (All Data)


Powertrain > Engine
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Starter Signal Starter signal Open or Close Open: Starter operating
Close: Starter not operating
Stored as Freeze Frame Data

Yes


Power Steering Signal Power steering switch signal ON or OFF ON: Power steering operating
Stored as Freeze Frame Data

Yes


Power Steer. Sig. Record Power steering switch signal ON or OFF ON: When steering wheel is first turned after ignition switch is turned to ON This signal status usually ON until ignition switch turned to OFF
Stored as Freeze Frame Data

Yes


Neutral Position SW Signal Park/neutral position switch status ON or OFF ON: Shift lever in P or N
Stored as Freeze Frame Data

Yes


Stop Light Switch Stop light switch ON or OFF ON: Brake pedal depressed
OFF: Brake pedal released
Stored as Freeze Frame Data

Yes


A/C Signal A/C switch status ON or OFF ON: A/C on
Stored as Freeze Frame Data

Yes


Closed Throttle Position SW Closed throttle position switch ON or OFF
·

ON: Throttle fully closed

·

OFF: Throttle open


Stored as Freeze Frame Data

Yes


Electrical Load Signal Electrical load signal ON or OFF ON: Headlights or defogger is turned ON
Stored as Freeze Frame Data

Yes



Check Mode (Check Mode)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Check Mode Check mode ON or OFF ON: Check mode on Refer to Check Mode Procedure.*
Stored as Freeze Frame Data

No


SPD Test Result Check mode result for vehicle speed sensor Compl or Incmpl -
Stored as Freeze Frame Data

No


*: Click hereEngine / Hybrid System>2TR-FE ENGINE CONTROL>SFI SYSTEM>CHECK MODE PROCEDURE


Various Vehicle Conditions 3 (All Data)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
# Codes(Include History) Number of codes Min.: 0, Max.: 255 0 This is the number of DTCs stored.
Stored as Freeze Frame Data

No


MIL MIL status ON or OFF OFF
Stored as Freeze Frame Data

No


Time after DTC Cleared Time after DTCs cleared Min.: 0 minutes, Max.: 65535 minutes Time after DTCs cleared This is the time elapsed after DTCs were cleared (or after the vehicle left the factory). Time elapsed after the ignition switch is turned off is not counted.
Stored as Freeze Frame Data

Yes


Distance from DTC Cleared Distance driven after DTCs cleared Min.: 0 km, Max.: 65535 km Distance driven after DTCs cleared This is the distance driven after DTCs were cleared (or after the vehicle left the factory).
Stored as Freeze Frame Data

Yes


Warmup Cycle Cleared DTC Warmup cycles after DTCs cleared Min.: 0, Max.: 255 - This is the number of warmup cycles after the DTCs were cleared.
This is the number of times the engine was warmed up* after DTCs were cleared (or after the vehicle left the factory).
*: An engine warmup is defined as the engine coolant temperature rising 20°C (36°F) or more and reaching a temperature of 70°C (158°F) or higher after the engine is started.
Stored as Freeze Frame Data

Yes


OBD Requirements OBD requirement - Not OBD compliant
Stored as Freeze Frame Data

No


Number of Emission DTC Emissions-related DTCs - - This is the number of emissions-related DTCs.
Stored as Freeze Frame Data

No


TC and TE1 TC and CG (TE1) terminals of DLC3 ON or OFF -
Stored as Freeze Frame Data

Yes



Various Vehicle Conditions 4 (All Data)


Powertrain > Engine
Tester Display Measurement Item Range Normal Condition Diagnostic Note
ACT VSV A/C cut status ON or OFF -
Stored as Freeze Frame Data

Yes


Idle Fuel Cut Fuel cut at idle ON or OFF ON: Fuel cut operating Idle Fuel Cut = "ON" when the throttle valve is fully closed and the engine speed is high.
Stored as Freeze Frame Data

Yes


FC TAU Fuel cut TAU (fuel cut during very light load) ON or OFF ON: Fuel cut operating This is the fuel cut performed under a very light load to prevent the engine combustion from becoming incomplete.
Stored as Freeze Frame Data

Yes



Various Vehicle Conditions 5 (Vehicle Information)


Powertrain > Engine > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Model Code Model code - - Used for identifying the model code: TGN###
Stored as Freeze Frame Data

No


Engine Type Engine type - - Used for identifying the engine type: 2TRFE
Stored as Freeze Frame Data

No


Cylinder Number Number of cylinders Min.: 0, Max.: 255 - Used for identifying the number of cylinders: 4
Stored as Freeze Frame Data

No


Transmission Type Transmission type - - Used for identifying the transmission type: MT, ECT 4th
Stored as Freeze Frame Data

No


Destination Destination - - Used for identifying the destination: W
Stored as Freeze Frame Data

No


Model Year Model year Min.: 1900, Max.: 2155 - Used for identifying the model year: 20##
Stored as Freeze Frame Data

No


System Identification System identification - - Used for identifying the engine system: Gasoline (gasoline engine)
Stored as Freeze Frame Data

No



Automatic Transmission 1 (All Data)


Powertrain > Engine
Tester Display Measurement Item Range Normal Condition Diagnostic Note
SPD (NC0) Input turbine speed Min.: 0 rpm, Max.: 12750 rpm
·

Lock-up ON (warmed up engine, other than O/D): Input turbine speed (NC0) is equal to the engine speed

·

Lock-up ON (warmed up engine, O/D): Input turbine speed (NC0) is 0 rpm

·

Lock-up OFF (idling with shift lever on N): Input turbine speed (NC0) is nearly equal to engine speed


Stored as Freeze Frame Data

Yes


SPD (SP2) Output shaft speed Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) Vehicle stopped: 0 km/h (0 mph) (output shaft speed is equal to vehicle speed)
Stored as Freeze Frame Data

Yes



Automatic Transmission 2 (AT)


Powertrain > Engine
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Shift SW Status (R Range) Park/neutral position switch status ON or OFF
·

ON: Shift lever in R

·

OFF: Shift lever not in R


When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the park/neutral position switch or shift cable may be incorrect.
HINT:

When failure still occurs even after adjusting these parts, refer to DTC P0705.


Stored as Freeze Frame Data

Yes


Shift SW Status (2 Range) Park/neutral position switch status ON or OFF
·

ON: Shift lever in 2

·

OFF: Shift lever not in 2


When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the park/neutral position switch or shift cable may be incorrect.
HINT:

When failure still occurs even after adjusting these parts, refer to DTC P0705.


Stored as Freeze Frame Data

Yes


Shift SW Status (L Range) Park/neutral position switch status ON or OFF
·

ON: Shift lever in L

·

OFF: Shift lever not in L


When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the park/neutral position switch or shift cable may be incorrect.
HINT:

When failure still occurs even after adjusting these parts, refer to DTC P0705.


Stored as Freeze Frame Data

Yes


Shift SW Status (3 Range) Park/neutral position switch status ON or OFF
·

ON: Shift lever in 3

·

OFF: Shift lever not in 3


When the shift lever position displayed on the intelligent tester differs from the actual position, the adjustment of the park/neutral position switch or shift cable may be incorrect.
HINT:

When failure still occurs even after adjusting these parts, refer to DTC P0705.


Stored as Freeze Frame Data

Yes


A/T Oil Temperature 3 No. 3 ATF temperature sensor value Min.: -40°C, Max.: 215°C
·

After stall test: Approximately 80°C (176°F)

·

Equal to ambient temperature when engine cold


If the value is -40°C (-40°F) or 215°C (419°F), the No. 3 ATF temperature sensor circuit is open or shorted.
Stored as Freeze Frame Data

Yes


Lock Up Solenoid Status Lock-up solenoid status ON or OFF Lock-up solenoid is:
·

ON: Operating

·

OFF: Not operating


Stored as Freeze Frame Data

Yes


Shift Status ECM gear shift command 1st, 2nd, 3rd or 4th Shift lever in D: 1st, 2nd, 3rd or 4th
Stored as Freeze Frame Data

Yes


SLT Solenoid Status Shift solenoid SLT status ON or OFF
·

ON: Accelerator pedal is released

·

OFF: Accelerator pedal is depressed


Stored as Freeze Frame Data

Yes



ACTIVE TEST


HINT:

Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the intelligent tester to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the intelligent tester on.


f.

Enter the following menus: Powertrain / Engine and ECT / Active Test.


g.

According to the display on the intelligent tester, perform the Active Test.

Powertrain > Engine > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Control the Injection Volume Change injection volume Between -12.5% and 24.8%
·

All injectors are tested at the same time.

·

Perform the test at 3000 rpm or less.

·

Injection volume can be changed in fine gradations within the control range.

·

Control the Injection Volume enables the checking and graphing of the heated oxygen sensor voltage output.

·

To conduct the test, enter the following menus: Active Test / Control the Injection Volume / O2S B1S1.

·

During the Active Test, air-fuel ratio feedback control and feedback learning are stopped.


Control the Injection Volume for A/F Sensor Change injection volume -12.5%, 0% or +12.5%
·

All injectors are tested at the same time.

·

Perform the test at 3000 rpm or less.

·

Control the Injection Volume for A/F Sensor enables the checking and graphing of the heated oxygen sensor voltage output.

·

To conduct the test, enter the following menus: Active Test / Control the Injection Volume for A/F Sensor / O2S B1S1.

·

During the Active Test, air-fuel ratio feedback control and feedback learning are stopped.

·

See waveform*1.


Activate the VSV for Evap Control Activate purge VSV control ON/OFF
·

The valve is opened with a 30% duty ratio.

·

See waveform*3.


Control the A/C Cut Signal A/C compressor cut ON/OFF -
Control the Fuel Pump / Speed Activate fuel pump ON/OFF Perform this test with the engine stopped.
Connect the TC and TE1 Turn on and off TC and TE1 connection ON/OFF
·

ON: TC and TE1 are connected.

·

OFF: TC and TE1 are disconnected.


Control the Idle Fuel Cut Prohibit Prohibit idling fuel cut control ON/OFF -
Control the ETCS Open/Close Slow Speed Throttle actuator Close/Open
Open: Throttle valve opens slowly
This test is possible when the following conditions are met:
·

Ignition switch is ON.


·

Engine is stopped.


·

Accelerator pedal is fully depressed (APP: 58 degrees or more).

·

Shift lever is in P.


Control the ETCS Open/Close Fast Speed Throttle actuator Close/Open
Open: Throttle valve opens quickly
·

Same as above.

·

See waveform*2.


Control the VVT Linear (Bank1) Control VVT (for intake side of bank 1) -128 to 127% (This value added to present camshaft timing oil control valve control duty)
100%: Maximum advance
-100%: Maximum retard
·

Engine stalls or idles roughly when the camshaft timing gear is operated by 100%.

·

Test is possible during idle.

·

See waveform*4.


Control the VVT System (Bank1) Turn camshaft timing oil control valve on and off ON/OFF
ON: VVT OCV Duty #1 100%
·

Engine stalls or idles roughly when the camshaft timing oil control valve is turned on.

·

Engine runs and idles normally when the camshaft timing oil control valve is off.


Control the Cylinder Fuel Cut Cylinder (#1 to #4) injector fuel cut ON/OFF Test is possible while the vehicle is stopped and the engine is idling.
Control the All Cylinders Fuel Cut Fuel cut for all cylinders ON/OFF Test possible while the vehicle is stopped and the engine is idling.


Reference Waveforms for Active Test
·

*1: Control the Injection Volume for A/F Sensor (Idling after warming up)

A253288
0.677,5.042 1.25,5.042 false 0.75,5.115 0.677,5.042 0.677,5.042 0.75,4.979 false 1.177,4.979 1.25,5.042 1.25,5.042 1.177,5.115 false 1.823,3.969 1.823,4.146 false 1.771,4.021 1.823,3.969 1.823,3.969 1.885,4.021 false 2.958,3.604 2.771,3.604 false 2.896,3.552 2.958,3.604 2.958,3.604 2.896,3.667 false 1.823,4.625 1.823,4.448 false 1.885,4.573 1.823,4.625 1.823,4.625 1.771,4.573 false 2.771,3.667 2.771,3.552 false 2.958,3.667 2.958,3.552 false 4.531,3.604 4.344,3.604 false 4.479,3.552 4.531,3.604 4.531,3.604 4.479,3.667 false 4.344,3.667 4.344,3.552 false 4.531,3.667 4.531,3.552 false 0.188,0.125 4.458,0.385 4.271,0.26 10 false Control the Injection Volume for A/F Sensor (+12.5% to -12.5%) 0.135,0.833 0.656,0.99 0.521,0.156 10 false +12.5% 0.135,1.979 0.656,2.135 0.521,0.156 10 false -12.5% 1.063,0.719 1.646,0.906 0.583,0.188 10 false +12.5% 2.615,0.719 3.177,0.896 0.563,0.177 10 false -12.5% 4.135,0.719 4.74,0.896 0.604,0.177 10 false +12.5% 5.615,0.719 6.25,0.906 0.635,0.188 10 false -12.5% 0.302,3.042 1.24,3.24 0.938,0.198 10 false O2S B1S1 [V] 0.26,3.635 0.625,3.802 0.365,0.167 10 false 1.0 V 0.344,4.792 0.625,4.958 0.281,0.167 10 false 0 V 0.604,5.156 1.365,5.333 0.76,0.177 10 false 10 seconds 3.563,4.99 3.719,5.146 0.156,0.156 10 false A 5.458,5 5.615,5.156 0.156,0.156 10 false B 1.979,4.458 2.333,4.604 0.354,0.146 10 false Lean 1.979,3.99 2.333,4.135 0.354,0.146 10 false Rich 2.531,3.167 3.281,3.344 0.75,0.177 10 false Time Delay 4.104,3.167 4.844,3.344 0.74,0.177 10 false Time Delay 3.531,4.865 3.688,5.021 0.156,0.156 10 false ▲ 5.427,4.865 5.583,5.021 0.156,0.156 10 false ▲

HINT:

During the Active Test, air-fuel ratio feedback control and feedback learning are stopped.


Tester Display Measurement Item/Range Normal Condition
Control the Injection Volume for A/F Sensor - ▲A ▲B
Active Test operation -12.5% +12.5%
O2S B1S1 0.03 V 0.85 V

HINT:
·

Usually, the value of O2S changes to 0.55 V or higher when the control value for Control the Injection Volume for A/F Sensor is changed to +12.5%.

·

Usually, the value of O2S drops below 0.4 V when the control value for Control the Injection Volume for A/F Sensor is changed to -12.5%.

·

If the sensor output voltage does not change (almost no reaction) while performing the Active Test, the sensor may be malfunctioning.



·

*2: Control the ETCS Open/Close Fast Speed [Active Test for electrical throttle control system] (Ignition switch ON)

A301297
0.333,0.521 7.063,0.917 6.729,0.396 10 Throttle Position Command [V] (Target Value) 0.167,1.219 0.563,1.448 0.396,0.229 10 5 V 0.167,1.948 0.563,2.177 0.396,0.229 10 0 V 2.688,1.344 3.667,1.656 0.979,0.313 10 Fully Open 2.688,1.74 3.667,2.052 0.979,0.313 10 Fully Closed 4.5,2.25 4.896,2.479 0.396,0.229 10 A 5.521,2.25 5.917,2.479 0.396,0.229 10 B 0.333,4.5 7.063,4.979 6.729,0.479 10 Throttle Motor Duty (Open) [%] 0.167,3.833 0.563,4.063 0.396,0.229 10 0 V 0.167,3.125 0.563,3.354 0.396,0.229 10 5 V 4.5,4.094 4.896,4.323 0.396,0.229 10 A 5.531,4.094 5.927,4.323 0.396,0.229 10 B 0.083,4.927 0.563,5.156 0.479,0.229 10 29 % 0.156,5.667 0.635,5.896 0.479,0.229 10 0 % 0.333,6.333 7.063,6.781 6.729,0.448 10 Throttle Motor Duty (Close) [%] 0.333,2.667 7.073,3.135 6.74,0.469 10 Throttle Position No. 1 [V] (Actual Value) 0.76,7.781 1.927,8.115 1.167,0.333 10 8 seconds 4.5,5.948 4.896,6.177 0.396,0.229 10 A 5.531,5.958 5.927,6.188 0.396,0.229 10 B 4.5,7.698 4.896,7.927 0.396,0.229 10 A 5.531,7.688 5.927,7.917 0.396,0.229 10 B 0.083,6.771 0.563,7 0.479,0.229 10 33 % 0.156,7.396 0.635,7.625 0.479,0.229 10 0 %

HINT:
·

Usually, Throttle Position Command (Target Value) and Throttle Position No. 1 (Actual Value) are almost the same.

·

If any DTCs related to the ETCS are stored, this Active Test does not function.



Tester Display Measurement Item/Range Normal Condition
Control the ETCS Open/Close Fast Speed - ▲A ▲B
Active Test operation Close Open
Throttle Position Command 2.597 V 0.742 V
Throttle Position No. 1 2.597 V 0.742 V
Throttle Motor Duty (Open) 14% 0%
Throttle Motor Duty (Close) 0% 10%

·

*3: Activate the VSV for Evap Control (Idling after warming up)

A301298
0.333,0.813 2.615,1.281 2.281,0.469 10 false EVAP Purge VSV 0.156,1.271 0.854,1.604 0.698,0.333 10 false ON 0.073,1.917 0.771,2.25 0.698,0.333 10 false OFF 2.156,2.26 2.854,2.594 0.698,0.333 10 false A 3.75,2.25 4.448,2.583 0.698,0.333 10 false B 0.333,2.667 2.615,3.135 2.281,0.469 10 false Short FT #1 [%] 0.26,3.188 0.75,3.5 0.49,0.313 10 false 0 0.26,3.823 0.75,4.135 0.49,0.313 10 false - 5 2.156,4.094 2.854,4.427 0.698,0.333 10 false A 3.76,4.094 4.458,4.427 0.698,0.333 10 false B 0.333,4.521 2.615,4.99 2.281,0.469 10 false Injector (Port) [μs] 0.073,4.948 0.563,5.26 0.49,0.313 10 false 2600 0.073,5.656 0.563,5.969 0.49,0.313 10 false 2200 2.156,5.948 2.854,6.281 0.698,0.333 10 false A 3.75,5.948 4.448,6.281 0.698,0.333 10 false B 0.333,6.344 2.615,6.813 2.281,0.469 10 false O2S B1S1 [V] 0.156,6.76 0.646,7.073 0.49,0.313 10 false 1.0 0.271,7.396 0.76,7.708 0.49,0.313 10 false 0 0.552,7.74 1.833,8.073 1.281,0.333 10 false 6 seconds 2.156,7.698 2.854,8.031 0.698,0.333 10 false A 3.75,7.698 4.448,8.031 0.698,0.333 10 false B

HINT:

Even when the Active Test is turned on (the purge VSV is opened 30%), air-fuel ratio feedback continues and control is performed so that the air-fuel ratio is the stoichiometric ratio. Therefore, by observing the change in "Short FT", it is possible to determine whether the purge VSV is actually open as well as the concentration of HC in the purge gas.


Tester Display Measurement Item/Range Normal Condition
Activate the VSV for Evap Control - ▲A ▲B
Active Test operation ON OFF
EVAP Purge VSV ON OFF
Short FT #1 -1.563% 0.000%
Injection (Port) 2288.0 μs 2430.0 μs
O2S B1S1 0.85 V 0.03 V

HINT:

The graphs and values above are for reference only because the fuel injection volume (compensation volume) varies depending on the HC density of the purge air from the canister.


·

*4: Control the VVT Linear (Bank 1)

A301299
0.333,0.25 4.521,0.635 4.188,0.385 10 Control the VVT Linear (Bank 1) 0.333,1.917 4.521,2.302 4.188,0.385 10 Engine Speed [rpm] 0.333,3.635 4.521,4.021 4.188,0.385 10 VVT Change Angle #1 [DegFR] 0.333,5.333 4.521,5.719 4.188,0.385 10 VVT OCV Duty #1 [%] 0.333,6.917 4.521,7.302 4.188,0.385 10 VVT Aim Angle #1 [%] 1.25,0.771 1.865,1.083 0.615,0.313 10 +20 % 3.927,0.771 4.542,1.083 0.615,0.313 10 +20 % 2.656,1.333 3.271,1.646 0.615,0.313 10 -20 % 4.813,1.333 5.427,1.646 0.615,0.313 10 -20 % 0.375,2.24 0.99,2.438 0.615,0.198 10 1797 0.458,3.229 1.073,3.427 0.615,0.198 10 575 0.406,3.885 1.021,4.083 0.615,0.198 10 56.0 0.49,4.802 1.104,5 0.615,0.198 10 0.0 1.76,5.167 2.375,5.365 0.615,0.198 10 A 3.073,5.167 3.688,5.365 0.615,0.198 10 B 0.49,6.417 1.104,6.615 0.615,0.198 10 0.0 0.49,8.073 1.104,8.271 0.615,0.198 10 0.0 0.406,7.25 1.021,7.448 0.615,0.198 10 33.9 0.417,5.635 1.031,5.833 0.615,0.198 10 53.9 1.76,6.76 2.375,6.958 0.615,0.198 10 A 3.083,6.771 3.698,6.969 0.615,0.198 10 B 1.76,8.448 2.375,8.646 0.615,0.198 10 A 3.083,8.448 3.698,8.646 0.615,0.198 10 B 4.01,8.5 5.125,8.75 1.115,0.25 10 5 seconds

Tester Display Measurement Item/Range Normal Condition
Control the VVT Linear (Bank 1) - ▲A ▲B
Active Test operation* +20% -20%
VVT Change Angle #1 54.9 DegFR 0.0 DegFR
VVT OCV Duty #1 53.9% 13.9%
VVT Aim Angle #1 33.9% 33.9%

HINT:
·

*: Change the control value for Control the VVT Linear to +20% or -20% in increments of 5%.

·

The Control the VVT Linear Active Test considers the value of VVT Aim Angle to be 0 and raises or lowers the duty ratio with respect to VVT Aim Angle.

·

The sum of the control value for the Control the VVT Linear Active Test and the value of VVT Aim Angle is approximately equal to the value of VVT OCV Duty.

·

When the control value for the Control the VVT Linear Active Test is changed a few times, there should not be a large discrepancy between VVT OCV Duty when the system starts advancing or retarding the timing and the rate of change of VVT Change Angle.