1.INSPECT SECURITY INDICATOR LIGHT ASSEMBLY
| *a | Component without harness connected
(Security Indicator Light Assembly) |
Apply battery voltage between the terminals of the indicator, and check the illumination of the security indicator light assembly.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 2 (LP)
Battery negative (-) → Terminal 1 (E) |
Illuminates |
If the positive (+) lead and the negative (-) lead are incorrectly connected, the security indicator light will not illuminate.
If the voltage is too low, the security indicator light will not illuminate.
If the result is not as specified, replace the security indicator light assembly.