This circuit is the power source circuit for the meter.
Inspect the fuses for circuits related to this system before performing the following procedure.
Disconnect the G19 combination meter assembly connector.
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G19-22 (EP) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G19-1 (B) - Body ground | Always | 11 to 14 V |
| G19-21 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
| G19-21 (IG+) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG