The back-up power source circuit for the air conditioning amplifier assembly is shown below. Power is supplied even after the ignition switch is turned off and is used for diagnostic trouble code memory, etc.
Inspect the fuses for circuits related to this system before performing the following procedure.
Disconnect the G94 air conditioning amplifier assembly connector.
| *a | Front view of wire harness connector
(to Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G94-5 (+B1) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG