1.RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
2.REMOVE FAN AND GENERATOR V BELT
3.DISCONNECT SUCTION HOSE SUB-ASSEMBLY
for LHD:
Remove the bolt and disconnect the suction hose sub-assembly from the compressor.
Remove the O-ring from the suction hose sub-assembly.
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering.
RHD:
Remove the bolt and disconnect the suction hose sub-assembly from the compressor.
Remove the O-ring from the suction hose sub-assembly.
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering.
4.DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE
LHD:
Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose from the compressor.
Remove the O-ring from the No. 1 cooler refrigerant discharge hose.
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering.
for RHD:
Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose from the compressor.
Remove the O-ring from the No. 1 cooler refrigerant discharge hose.
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering.
5.REMOVE COOLER COMPRESSOR ASSEMBLY
for LHD:
Disconnect the connector.
Remove the 4 bolts and cooler compressor assembly.
for RHD:
Disconnect the connector.
Remove the 4 bolts and cooler compressor assembly.