Home › Vehicle Interior › HEATING / AIR CONDITIONING › FRONT EVAPORATOR TEMPERATURE SENSOR
RM1880E _58 Vehicle Interior _013245 HEATING / AIR CONDITIONING _0068675 FRONT EVAPORATOR TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  FRONT EVAPORATOR TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 1.INSPECT NO. 1 COOLER THERMISTOR

E184474
0.26,0.906 0.385,0.563 true 0.115,0.052 0.302,0.229 0.188,0.177 10 false *a 0.375,0.385 0.563,0.563 0.188,0.177 10 false *b 0.125,1.594 0.313,1.771 0.188,0.177 10 false *c 0.042,1.823 0.354,2 0.313,0.177 10 false 10.0 0.146,2.031 0.458,2.208 0.313,0.177 10 false 9.0 0.146,2.26 0.458,2.438 0.313,0.177 10 false 8.0 0.146,2.469 0.458,2.646 0.313,0.177 10 false 7.0 0.146,2.698 0.458,2.875 0.313,0.177 10 false 6.0 0.146,2.917 0.458,3.094 0.313,0.177 10 false 5.0 0.146,3.135 0.458,3.313 0.313,0.177 10 false 4.0 0.146,3.344 0.458,3.521 0.313,0.177 10 false 3.0 0.146,3.573 0.458,3.75 0.313,0.177 10 false 2.0 0.146,3.781 0.458,3.958 0.313,0.177 10 false 1.0 3.198,4.104 3.396,4.281 0.198,0.177 10 false 30 2.49,4.104 2.688,4.281 0.198,0.177 10 false 20 1.76,4.104 1.958,4.281 0.198,0.177 10 false 10 1.094,4.104 1.292,4.281 0.198,0.177 10 false 0 0.292,4.104 0.531,4.281 0.24,0.177 10 false -10 0.146,3.99 0.458,4.167 0.313,0.177 10 false 0 1.771,4.354 1.958,4.531 0.188,0.177 10 false *d
*a Component without harness connected
(No. 1 Cooler Thermistor (Front Evaporator Temperature Sensor))
*b Sensor Part
*c Resistance kΩ
*d Temperature °C (°F)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 -10°C (14°F) 7.30 to 9.10 kΩ
-5°C (23°F) 5.65 to 6.95 kΩ
0°C (32°F) 4.40 to 5.35 kΩ
5°C (41°F) 3.40 to 4.15 kΩ
10°C (50°F) 2.70 to 3.25 kΩ
15°C (59°F) 2.14 to 2.58 kΩ
20°C (68°F) 1.71 to 2.05 kΩ
25°C (77°F) 1.38 to 1.64 kΩ
30°C (86°F) 1.11 to 1.32 kΩ


If the resistance is not as specified, replace the No. 1 cooler thermistor (front evaporator temperature sensor).

NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (refer to the graph).