Home › Vehicle Interior › HEATING / AIR CONDITIONING › SOLAR SENSOR(for Automatic Air Conditioning System)
RM1880E _58 Vehicle Interior _013245 HEATING / AIR CONDITIONING _0068676 SOLAR SENSOR(for Automatic Air Conditioning System) G

HEATING / AIR CONDITIONING  SOLAR SENSOR(for Automatic Air Conditioning System)  INSPECTION  


PROCEDURE

Hide 1.INSPECT COOLER (SOLAR SENSOR) THERMISTOR

E225715
0.177,0.125 0.49,0.469 0.313,0.344 10 false *a 1.844,1.25 2.052,1.469 0.208,0.219 10 false 1 1.552,1.25 1.76,1.469 0.208,0.219 10 false 2
*a Component with harness connected
(Cooler (Solar Sensor) Thermistor)


a.

Connect the connector.


b.

Turn the ignition switch to ON.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
1 (SS+) - 2 (SS-) Sensor not exposed to sunlight or inspection light Below 0.8 V
Sensor exposed to sunlight or inspection light 0.8 to 4.3 V


If the resistance is not as specified, replace the cooler (solar sensor) thermistor.

HINT:
·

Check from the rear of the connector while it is connected to the cooler (solar sensor) thermistor.

·

Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler (solar sensor) thermistor.