HEATING / AIR CONDITIONING  AIR CONDITIONING PRESSURE SENSOR  INSPECTION  


PROCEDURE

Hide 1.INSPECT NO. 1 PRESSURE SWITCH (for LHD)

E235434
3.094,1.021 2.771,1.021 true 3.688,1.01 4.01,1.01 true 3.375,1.115 3.375,1.688 3.375,1.688 3.146,1.688 true 3.375,0.885 3.375,0.313 3.375,0.313 3.688,0.313 true 0.094,0.073 0.281,0.25 0.188,0.177 10 false *a 3.75,0.229 4.042,0.5 0.292,0.271 10 false 1 4.094,0.948 4.365,1.177 0.271,0.229 10 false 2 2.531,0.938 2.75,1.177 0.219,0.24 10 false 3 2.917,1.615 3.198,1.802 0.281,0.188 10 false 4 5.896,2.875 6.094,3.042 0.198,0.167 10 false *c 4.052,3.333 4.25,3.5 0.198,0.167 10 false *e 4.198,3.469 4.896,3.656 0.698,0.188 10 false 1,226 kPa 3.51,3.677 4.927,3.865 1.417,0.188 10 false (12.5 kgf/cm2,178 psi) 5.146,3.677 6.594,3.865 1.448,0.188 10 false (12.5 kgf/cm2,178 psi) 5.146,3.469 5.844,3.656 0.698,0.188 10 false 1,520 kPa 0.99,2.813 1.188,2.979 0.198,0.167 10 false *b 1.667,2.729 1.865,2.896 0.198,0.167 10 false *c 2.417,2.813 2.615,2.979 0.198,0.167 10 false *d 0.906,3.771 1.104,3.938 0.198,0.167 10 false *e 2.594,3.74 2.792,3.906 0.198,0.167 10 false *e 0.688,3.375 1.26,3.542 0.573,0.167 10 false 196 kPa 0.396,3.552 1.667,3.719 1.271,0.167 10 false (2.0 kgf/cm2,28 psi) 2.302,3.365 2.99,3.531 0.688,0.167 10 false 3140 kPa 2.052,3.542 3.375,3.708 1.323,0.167 10 false (32.0 kgf/cm2,28 psi) 0.344,2.146 0.531,2.292 0.188,0.146 10 false *A 3.823,2.146 4,2.292 0.177,0.146 10 false *B
*A for Magnet Clutch Control *B for Cooling Fan Control
*a Component without harness connected
(Air Conditioning Pressure Sensor)
*b Low Pressure
*c On (Below 1.0 Ω) *d High Pressure
*e Off (10 kΩ or higher) - -


a.

Install a manifold gauge set.


b.

for Magnet Clutch Control:

i.

Connect the positive (+) lead from an ohmmeter to terminal 4 and the negative (-) lead to terminal 1.


ii.

Check the resistance between terminals when refrigerant pressure is charged as shown in the illustration.

If the operation is not as specified, replace the No. 1 pressure switch (air conditioning pressure sensor).



c.

for Cooling Fan Control:

i.

Connect the positive (+) lead from an ohmmeter to terminal 2 and the negative (-) lead to terminal 3.


ii.

Check the resistance between terminals when refrigerant pressure is charged as shown in the illustration.

If the operation is not as specified, replace the No. 1 pressure switch (air conditioning pressure sensor).



Hide 2.INSPECT NO. 1 PRESSURE SWITCH (for RHD)

E225692
1.448,1.271 1.167,0.771 true 1.76,1.271 2.063,0.74 true 0.198,0.135 0.552,0.479 0.354,0.344 10 false *a 0.729,2.667 1.073,3.01 0.344,0.344 10 false *b 2.104,0.594 2.458,0.938 0.354,0.344 10 false 2 1.521,2.667 1.865,3.01 0.344,0.344 10 false *c 2.25,2.667 2.594,3.01 0.344,0.344 10 false *d 0.729,3.76 1.073,4.104 0.344,0.344 10 false *e 2.385,3.76 2.729,4.104 0.344,0.344 10 false *e 0.448,3.448 1.385,3.802 0.938,0.354 10 false 196 kPa 0.156,3.594 1.469,4 1.313,0.406 10 false (2.0 kgf/cm2, 28 psi) 2.375,3.438 3.313,3.792 0.938,0.354 10 false 3140 kPa 1.875,3.583 3.333,3.906 1.458,0.323 10 false (32.0 kgf/cm2, 455 psi) 1.042,0.615 1.396,0.958 0.354,0.344 10 false 1
*a Component without harness connected
(Air Conditioning Pressure Sensor)
*b Low Pressure
*c On (Below 1.0 Ω)
*d High Pressure
*e Off (10 kΩ or higher)


a.

Install a manifold gauge set.


b.

Connect the positive (+) lead from an ohmmeter to terminal 1 and the negative (-) lead to terminal 2.


c.

Check the resistance between terminals when refrigerant pressure is charged as shown in the illustration.

If the operation is not as specified, replace the No. 1 pressure switch (air conditioning pressure sensor).