1.INSPECT NO. 1 COOLER WIRE
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A1-B1 | Always | Below 1 Ω |
| A2-B2 | Always | Below 1 Ω |
| A3-B3 | Always | Below 1 Ω |
| A4-B4 | Always | Below 1 Ω |
| A5-B5 | Always | Below 1 Ω |
| A6-B6 | Always | Below 1 Ω |
| A7-B7 | Always | Below 1 Ω |
| A8-B8 | Always | Below 1 Ω |
| A9-B9 | Always | Below 1 Ω |
| A10-B10 | Always | Below 1 Ω |
| A11-B11 | Always | Below 1 Ω |
| A12-B12 | Always | Below 1 Ω |
| A13-B13 | Always | Below 1 Ω |
| A14-B14 | Always | Below 1 Ω |
| A15-B15 | Always | Below 1 Ω |
If the result is not as specified, replace the No. 1 cooler wire.