ON-VEHICLE INSPECTION
Inspection · Vehicles built from Aug 2013
| OPERATION CHECK |
Disconnect the vacuum hose from the vacuum pump.
Connect the hose of a vacuum gauge to the pump.

Text in Illustration *1
Vacuum Gauge
*2
Plug
Insert a plug into the other hose of the gauge.
Start the engine and warm it up for more than 2 minutes.
With the engine idling, measure the negative pressure of the pump.
- Standard negative pressure:
- More than 86.7 kPa (650 mmHg, 26 in.Hg)
Remove the gauge from the pump.
Connect the hose to the pump with the clip.