2013-2015 Land Cruiser Prado · Service Manual Brake

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Aug 2013


OPERATION CHECK
  1. Disconnect the vacuum hose from the vacuum pump.

  1. C106115E03
    Connect the hose of a vacuum gauge to the pump.
    Text in Illustration 
    *1
    Vacuum Gauge
    *2
    Plug

  1. Insert a plug into the other hose of the gauge.

  1. Start the engine and warm it up for more than 2 minutes.

  1. With the engine idling, measure the negative pressure of the pump.

    Standard negative pressure:
    More than 86.7 kPa (650 mmHg, 26 in.Hg)

  1. Remove the gauge from the pump.

  1. Connect the hose to the pump with the clip.