Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Aug 2013 – Jul 2014from Aug 2014
DESCRIPTION
Refer to "SRS Warning Light Remains ON" (Click here).
WIRING DIAGRAM
Refer to "SRS Warning Light Remains ON" (Click here).
INSPECTION PROCEDURE
NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected (Click here).
1. CHECK BATTERY
Measure the voltage of the battery.
Standard voltage:
11 to 14 V
NG
REPLACE OR RECHARGE BATTERY
OK
2. CHECK CONNECTORS
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the combination meter.
OK:
The connectors are properly connected.
NG
CONNECT CONNECTORS PROPERLY
OK
3. CHECK HARNESS AND CONNECTOR (SOURCE VOLTAGE OF COMBINATION METER)
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the G6 connector from the combination meter.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
G6-28 (IG+) - G6-21 (E1)
Ignition switch ON
11 to 14 V
G6-26 (B) - G6-21 (E2)
Always
11 to 14 V
Text in Illustration
*a
Front view of wire harness connector (to Combination Meter)
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
4. CHECK SRS WARNING LIGHT (SHORT TO GROUND)
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Connect the connector to the combination meter.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Check the SRS warning light condition.
NOTICE:
Make sure that nobody is in the vehicle.
OK:
After the primary check period, the SRS warning light goes off for approximately 10 seconds and then remains on.
HINT:
The primary check period is approximately 6 seconds after the ignition switch is turned to ON.