INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT CRANKSHAFT POSITION SENSOR |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
Cold
19 to 32 Ω
1 - 2
Hot
24 to 37 Ω
- NOTICE:
- In the chart above, the terms "Cold" and "Hot" refer to the temperature of the sensor. "Cold" means approximately -10 to 50°C (14 to 122°F). "Hot" means approximately 50 to 100°C (122 to 212°F).