2013-2015 Land Cruiser Prado · Service Manual Engine / Hybrid System

INSPECTION

Inspection · Vehicles built from Aug 2013


INSPECT CANISTER (for Single Tank Type)
  1. Visually check the canister for cracks or damage.
    If cracks or damage is found, replace the canister.

  1. A172207E03
    Using SST, inspect the canister.
    SST
    09992-00242  

    OK:
    Measurement Condition
    Specified Condition
    Ports B and C closed, vacuum applied to port A [1.96 kPa (15 mmHg, 0.579 in.Hg)]
    No leak
    Port C closed, vacuum applied to port A [1.96 kPa (15 mmHg, 0.579 in.Hg)]
    Air flows from port B
    Port C closed, air blow into port A [4.71 kPa (0.05 kgf/cm2, 0.7 psi)]
    Air flows from port B
    Air blow into port A [4.71 kPa (0.05 kgf/cm2, 0.7 psi)]
    Air flows from both ports B and C

    Text in Illustration 
    *1
    Port A
    *2
    Port B
    *3
    Port C
    If the result is not as specified, replace the canister.


INSPECT CANISTER (for Double Tank Type)
  1. Visually check the canister for cracks or damage.
    If cracks or damage is found, replace the canister.

  1. A126192E03
    Using SST, inspect the canister.
    SST
    09992-00242  

    OK:
    Measurement Condition
    Specified Condition
    Ports B and C closed, vacuum applied to port A [1.96 kPa (15 mmHg, 0.579 in.Hg)]
    No leak
    Port C closed, air blow into port A [4.71 kPa (0.05 kgf/cm2, 0.7 psi)]
    Air flows from port B
    Port C closed, air blow into port B [4.71 kPa (0.05 kgf/cm2, 0.7 psi)]
    Air flows from port A
    Air blow into port A [4.71 kPa (0.05 kgf/cm2, 0.7 psi)]
    Air flows from both ports B and C

    Text in Illustration 
    *1
    Port A
    *2
    Port B
    *3
    Port C
    If the result is not as specified, replace the canister.

← REMOVAL (from Aug 2013)INSTALLATION (from Aug 2013) →