2013-2015 Land Cruiser Prado · Service Manual Engine / Hybrid System

ON-VEHICLE INSPECTION

Inspection · Vehicles built from Aug 2013


INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR

  1. Inspect the power source voltage.

    1. Disconnect the manifold absolute pressure sensor connector.

    2. A225145E01
      Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Tester Connection
      Switch Condition
      Specified Condition
      C83-3 (VC) - C83-1 (E)
      Ignition switch ON
      4.75 to 5.25 V

      Text in Illustration 
      *a
      Front view of wire harness connector
      (to Manifold Absolute Pressure Sensor)
      If the result is not as specified, inspect the wire harness or ECM (Click here).

    3. Connect the manifold absolute pressure sensor connector.

  1. Check the power supply.

    1. Turn the ignition switch ON.

    2. Disconnect the vacuum hose from the manifold absolute pressure sensor.

    3. A225146E01
      Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Tester Connection
      Condition
      Specified Condition
      C91-5 (PIM) - C91-16 (EPIM)
      -13.3 kPa (100 mmHg, 3.94 in.Hg)
      0.0 to 0.3 V
      -26.6 kPa (199 mmHg, 7.85 in.Hg)
      0.1 to 0.4 V
      -40 kPa (300 mmHg, 11.81 in.Hg)
      0.3 to 0.6 V

      Text in Illustration 
      *a
      Component without harness connected
      (ECM)
      V100135
      Vacuum

      HINT:
      The values in the "Condition" column are gauge pressures.

      If the result is not as specified, replace the manifold absolute pressure sensor.

    4. A225147E01
      Using SST, measure the voltage according to the value(s) in the table below.
      SST
      09992-00242  

      Standard Voltage:
      Tester Connection
      Condition
      Specified Condition
      C91-5 (PIM) - C91-16 (EPIM)
      19.6 kPa (0.20 kgf/cm2, 2.84 psi)
      0.1 to 0.4 V
      39.2 kPa (0.40 kgf/cm2, 5.69 psi)
      0.3 to 0.6 V
      58.8 kPa (0.60 kgf/cm2, 8.53 psi)
      0.5 to 0.8 V
      78.5 kPa (0.80 kgf/cm2, 11.4 psi)
      0.7 to 1.1 V
      98.0 kPa (1.00 kgf/cm2, 14.2 psi)
      0.9 to 1.3 V

      Text in Illustration 
      *a
      Component without harness connected
      (ECM)
      V100135
      Pressure

      HINT:
      The values in the "Condition" column are gauge pressures.

      If the result is not as specified, replace the manifold absolute pressure sensor.

← COMPONENTS (from Aug 2013)REMOVAL (from Aug 2013) →