INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT MASS AIR FLOW METER |
Check the output voltage.
Apply battery voltage across terminals 1 (+B) and 2 (E2G).

- NOTICE:
- While using the battery during inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
Using a voltmeter, connect the positive (+) tester probe to terminal 3 (VG) and the negative (-) tester probe to terminal 2 (E2G).
Blow air into the mass air flow meter and check that the voltage fluctuates.
If the result is not as specified, replace the mass air flow meter.Text in Illustration 

Air
Perform a visual check for any foreign matter on the platinum hot wire (heater) of the mass air flow meter shown in the illustration.

- OK:
- There is no foreign matter.
If the result is not as specified, replace the mass air flow meter.Text in Illustration *1
Platinum Hot Wire (Heater)
Check the intake air temperature sensor.


Text in Illustration *1
Resistance
*2
Temperature
*3
Acceptable
-
-
*a
Component without harness connected
(Mass Air Flow Meter)
-
-
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
4 (THA) - 5 (E2)
-20°C (-4°F)
12.5 to 16.9 kΩ
20°C (68°F)
2.19 to 2.67 kΩ
60°C (140°F)
0.50 to 0.68 kΩ