DATA LIST / ACTIVE TEST
System information · Vehicles built from Aug 2013
| DATA LIST |
- HINT:
- Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
- NOTICE:
- In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus:
- Body / Air Conditioner / Data List.
- Powertrain / Engine and ECT / Data List.
- Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Room Temperature Sensor
Cooler thermistor (room temperature sensor) /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature for front seat displayed
Open in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).
Ambient Temp Sensor
Cooler thermistor (ambient temperature sensor) /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed
Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).
Adjusted Ambient Temp
Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)
Adjusted ambient temperature displayed
-
Evaporator Fin Thermistor
No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed
Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).
Evaporator Target Temp
Target evaporator temperature /
Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Target evaporator temperature displayed
-
Solar Sensor (D Side)
Automatic light control sensor (solar sensor) / Min.: 0, Max.: 255
Driver side solar sensor voltage increases as brightness increases
Open in the circuit: 0.
Short in the circuit: 255.
Solar Sensor (P Side)
Automatic light control sensor (solar sensor) / Min.: 0, Max.: 255
Passenger side solar sensor voltage increases as brightness increases
Open in the circuit: 0.
Short in the circuit: 255.
Engine Coolant Temp
Engine coolant temperature /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
-
Set Temperature (D Side)
Driver side set temperature /
MAX COLD: 0°C (32°F)
MAX HOT: 30°C (86°F)
Driver side set temperature displayed
-
Set Temperature (P Side)
Passenger side set temperature /
MAX COLD: 0°C (32°F)
MAX HOT: 30°C (86°F)
Passenger side set temperature displayed
-
Blower Motor Speed Level
Blower with fan motor sub-assembly speed level / Min.: 0, Max.: 31
Increases in range from 0 to 31 as blower with fan motor sub-assembly speed increases
-
Regulator Pressure Sensor
Refrigerant pressure sensor /
Min.: -0.4566 MPa
Max.: 3.2943 MPa
Actual refrigerant pressure displayed
-
Room Temp Sensor (Rear)*1
Cooler thermistor (rear room temperature sensor) /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual rear cabin temperature displayed
-
Ambient Temp Sens (Rear)*1
Rear evaporator temperature sensor /
Min.: -29.7°C (-21.46°F)
Max.: 59.25°C (138.65°F)
Actual rear evaporator temperature displayed
-
Set Temperature (Rear)*1
Rear set temperature /
Min.: 0°C (32°F)
Max.: 30°C (86°F)
Actual rear set temperature displayed
-
Blower Motor Level (Rear)*1
Rear blower with fan motor sub-assembly speed level / Min.: 0, Max.: 31
Increases in range from 0 to 31 as rear blower with fan motor sub-assembly speed increases
-
Air Outlet Servo Pulse (R)*1
Rear mode damper servo sub-assembly target pulse / Min.: 0, Max.: 255
83 (pulse): FACE
41 (pulse): B/L
7 (pulse): FOOT
-
Air Outlet Servo Actual Pls(R)*1
Rear mode damper servo sub-assembly actual pulse / Min.: 0, Max.: 255
83 (pulse): FACE
41 (pulse): B/L
7 (pulse): FOOT
-
Air Mix Servo Targ Pulse(R)*1
Rear air mix damper servo sub-assembly target pulse / Min.: 0, Max.: 255
9 (pulse): MAX COOL
54 (pulse): MAX HOT
-
Air Mix Servo Actual Pulse(R)*1
Rear air mix damper servo sub-assembly actual pulse / Min.: 0, Max.: 255
9 (pulse): MAX COOL
54 (pulse): MAX HOT
-
Air Mix Servo Targ Pulse (D)
Damper servo sub-assembly (driver side air mix damper servo) target pulse / Min.: 0, Max.: 255
for LHD: - 107 (pulse): MAX COOL
- 26 (pulse): MAX HOT
- 112 or 127 (pulse): MAX COOL
- 21 or 31 (pulse): MAX HOT
-
Air Mix Servo Actual Pulse (D)
Damper servo sub-assembly (driver side air mix damper servo) actual pulse / Min.: 0, Max.: 255
for LHD: - 107 (pulse): MAX COOL
- 26 (pulse): MAX HOT
- 112 or 127 (pulse): MAX COOL
- 21 or 31 (pulse): MAX HOT
-
Air Mix Servo Targ Pulse (P)
Damper servo sub-assembly (front passenger side air mix damper servo) target pulse / Min.: 0, Max.: 255
for LHD: - 112 or 127 (pulse): MAX COOL
- 21 or 31 (pulse): MAX HOT
- 107 (pulse): MAX COOL
- 26 (pulse): MAX HOT
-
Air Mix Servo Actual Pulse (P)
Damper servo sub-assembly (front passenger side air mix damper servo) actual pulse / Min.: 0, Max.: 255
for LHD: - 112 or 127 (pulse): MAX COOL
- 21 or 31 (pulse): MAX HOT
- 107 (pulse): MAX COOL
- 26 (pulse): MAX HOT
-
Air Outlet Servo Pulse (D)
Damper servo sub-assembly (mode damper servo) target pulse / Min.: 0, Max.: 255
15 (pulse): FACE 1
23 (pulse): FACE 2
41 (pulse): B/L
65 or 73 (pulse): FOOT
83 or 95 (pulse): F/D
113 (pulse): DEF
-
Air Outlet Servo Actu Pulse (D)
Damper servo sub-assembly (mode damper servo) actual pulse / Min.: 0, Max.: 255
15 (pulse): FACE 1
23 (pulse): FACE 2
41 (pulse): B/L
65 or 73 (pulse): FOOT
83 or 95 (pulse): F/D
113 (pulse): DEF
-
Air Inlet Damper Targ Pulse
Recirculation damper servo sub-assembly target pulse / Min.: 0, Max.: 255
7 (pulse): Recirculation
28 (pulse): Fresh
-
Air Inlet Damper Actual Pulse
Recirculation damper servo sub-assembly actual pulse / Min.: 0, Max.: 255
7 (pulse): Recirculation
28 (pulse): Fresh
-
Electric Heater Active Level*2
Number of electric heaters operating / Min.: 0, Max.: 3
-
-
Shift Set Temperature
Set temperature shift / 2C incr, 1C incr, Normal, 1C decr or 2C decr
Customized setting displayed
-
Air Inlet Mode
Air inlet mode / Auto or Manual
Customized setting displayed
-
Compressor Mode
Compressor mode / Auto or Manual
Customized setting displayed
-
Add Foot Air in FACE Mode
Add foot air in face mode / ON or OFF
Customized setting displayed
-
Foot/DEF Auto Mode
Foot/Def auto mode / ON or OFF
Customized setting displayed
-
Foot/DEF Auto Blow Up
Foot/Def auto blower level function / ON or OFF
Customized setting displayed
-
IDLE UP/PWR HEAT Switch*3
Idle up switch or heater switch assembly / ON or OFF
ON: Idle up switch or heater switch assembly on
OFF: Idle up switch and heater switch assembly off
-
Number of Trouble Codes
Number of trouble codes / Min.: 0, Max.: 255
Number of DTCs stored
-
- *1: w/ Rear Air Conditioning System
- *2: w/ PTC Heater
- *3: w/ Idle Up Switch or Viscous Heater
Engine and ECT Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
A/C Signal
A/C signal / ON or OFF
ON: A/C switch on
OFF: A/C switch off
-
- 107 (pulse): MAX COOL
| ACTIVE TEST |
- HINT:
- Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
According to the display on the intelligent tester, perform the Active Test.
Air Conditioner Tester Display
Test Part
Control Range
Diagnostic Note
Blower Motor
Blower with fan motor sub-assembly
Min.: 0, Max.: 31
-
Magnetic Clutch Relay
Magnet clutch relay operation
ON or OFF
-
Defogger Relay (Rear)
Rear window defogger relay operation
ON or OFF
-
Electrical Fan*1
Motor cooling fan operation
ON or OFF
-
Heater Active Level*2
Heater level
Min.: 0, Max.: 3
-
Air Mix Servo Targ Pulse (D)
Damper servo sub-assembly (driver side air mix damper servo) target pulse
Min.: 0, Max.: 255
-
Air Mix Servo Targ Pulse (P)
Damper servo sub-assembly (front passenger side air mix damper servo) target pulse
Min.: 0, Max.: 255
-
Air Outlet Servo Pulse (D)
Damper servo sub-assembly (mode damper servo) pulse
Min.: 0, Max.: 255
-
Air Inlet Damper Targ Pulse
Recirculation damper servo sub-assembly target pulse
Min.: 0, Max.: 255
-
Rear Blower Motor*3
Rear blower with fan motor sub-assembly
Min.: 0, Max.: 31
-
Rear Air Mix Servo Targ Pulse*3
Rear air mix damper servo sub-assembly target pulse
Min.: 0, Max.: 255
-
Viscous Heater*4
Viscous heater operation
ON or OFF
-
A/O Servo Pulse(Rr D)*3
Rear mode damper servo sub-assembly pulse
Min.: 0, Max.: 255
-
- *1: except 1KD-FTV and w/ Rear Air Conditioning System
- *2: w/ PTC Heater
- *3: w/ Rear Air Conditioning System
- *4: w/ Viscous Heater
- *1: except 1KD-FTV and w/ Rear Air Conditioning System