INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT HEIGHT CONTROL COMPRESSOR (EXHAUST VALVE) |
Measure the resistance of the exhaust valve.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
2 (L) - 1 (B)
15 to 25°C (59 to 77°F)
10 to 14 Ω
Text in Illustration *a
Component without harness connected
(Exhaust Valve)
Check the exhaust valve operation.

Connect a positive (+) lead from the battery to terminal 2 (B), and a negative (-) lead to terminal 1 (L).
Check the operating sound of the height control valve.
- OK:
- It makes an operating sound.
If the result is not as specified, replace the height control compressor.Text in Illustration *a
Component without harness connected
(Exhaust Valve)
| INSPECT HEIGHT CONTROL COMPRESSOR (COMPRESSOR MOTOR) |
Check the compressor operation.
Apply 12 V battery voltage to the compressor motor and check the operation of the motor.

- OK:
Measurement Condition
Specified Value
12 V battery positive (+) → Terminal 1 (B)
12 V battery negative (-) → Terminal 2 (E)
Motor operates
Text in Illustration *a
Component without harness connected
(Compressor Motor)
- NOTICE:
- Do not operate the height control compressor for 60 seconds or more.
- Stop applying voltage immediately if the compressor stops operating because a short will occur and the compressor motor will lock up, causing a flow of excessive current.
- Do not operate the height control compressor for 60 seconds or more.