U1002 Lost Communication with Gateway Module (Power Management2)
Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
- The power management control ECU stores this DTC when no signals can be received from the ECUs that have been memorized as those connected to the power management bus.
- When the power management control ECU receives a response signal from the ECUs connected to the power management bus, the power management control ECU recognizes and memorizes that the ECU is connected to the power management bus. Based on this memorized data, the power management control ECU monitors for malfunctions in the ECUs connected to the power management bus when communicating with those ECUs. If the power management control ECU cannot receive response signals from the ECUs that have been memorized as those connected to the power management bus, the power management control ECU determines that a malfunction exists.
- If 2 or more DTCs are output during the DTC check, one side of the CAN branch wire may be open (one side of the CANH [branch wire]/CANL [branch wire] of the ECU and/or sensor is open).
| DTC Code |
DTC Detection Condition |
Trouble Area |
| U1002 |
Lost communication with the gateway module (Power Management2). |
|
WIRING DIAGRAM




INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
- HINT:
- Operating the engine switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the CAN main wire and the CAN branch wire.
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the airbag system.
- NOTICE:
- After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
- After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
| NEXT | |
| 2. CHECK CAN BUS WIRE (CHECK CAN MAIN WIRE FOR DISCONNECTION, CHECK BUS LINE FOR SHORT) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
Resistance: Malfunction
G51-12 (CA3P) - G51-11 (CA3N)
Engine switch off
54 to 69 Ω
Below 53 Ω: Short in line
G51-12 (CA3P) - G51-11 (CA3N)
Engine switch off
54 to 69 Ω
Higher than 70 Ω: Open in CAN main bus line
G51-12 (CA3P) - G51-1 (AM22)
Engine switch off
6 kΩ or higher
Below 6 kΩ: +B short
G51-11 (CA3N) - G51-1 (AM22)
Engine switch off
6 kΩ or higher
Below 6 kΩ: +B short
G51-12 (CA3P) - G51-6 (GND)
Engine switch off
200 Ω or higher
Below 200 Ω: Ground short
G51-11 (CA3N) - G51-6 (GND)
Engine switch off
200 Ω or higher
Below 200 Ω: Ground short
Text in Illustration *a
Component with harness connected
(Power Management Control ECU)
Result Result
Proceed to
NG - Open in CAN main bus line
A
NG - Short in line
- +B short
- Ground short
B
OK
C
|
|
||||
|
|
||||
| A | |
| 3. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 3 JUNCTION CONNECTOR - ECM) |
![]() ![]() |
Disconnect the G98 No. 3 junction connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G98-9 (CANH) - G98-20 (CANL)
Engine switch off
108 to 132 Ω
Text in Illustration *a
Rear view of wire harness connector
(to No. 3 Junction Connector)
|
|
||||
| OK | |
| 4. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 3 JUNCTION CONNECTOR - POWER MANAGEMENT CONTROL ECU) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G98-11 (CANH) - G98-22 (CANL)
Engine switch off
108 to 132 Ω
Text in Illustration *a
Rear view of wire harness connector
(to No. 3 Junction Connector)
|
|
||||
| OK | ||
| ||
| 5. CONNECT CONNECTOR |
Reconnect the G98 No. 3 junction connector.
| NEXT | |
| 6. CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM - NO. 3 JUNCTION CONNECTOR) |
Disconnect the G56*1 or G57*2 ECM connector.
- *1: for 1GR-FE
- *2: for 1KD-FTV


- *1: for 1GR-FE
| *A |
for 1GR-FE |
*B |
for 1KD-FTV |
| *a |
Front view of wire harness connector (to ECM) |
- |
- |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for 1GR-FE Tester Connection
Switch Condition
Specified Condition
G56-34 (CANP) - G56-33 (CANN)
Engine switch off
108 to 132 Ω
for 1KD-FTV Tester Connection
Switch Condition
Specified Condition
G57-20 (CANP) - G57-21 (CANN)
Engine switch off
108 to 132 Ω
Result Result
Proceed to
OK (for 1GR-FE)
A
OK (for 1KD-FTV)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||
| 7. CONNECT CONNECTOR |
Reconnect the G98 No. 3 junction connector.
| NEXT | |
| 8. CHECK FOR OPEN IN CAN BUS MAIN WIRE (POWER MANAGEMENT CONTROL ECU - NO. 3 JUNCTION CONNECTOR) |
Disconnect the G51 power management control ECU connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G51-12 (CA3P) - G51-11 (CA3N)
Engine switch off
108 to 132 Ω
Text in Illustration *a
Rear view of wire harness connector
(to Power Management Control ECU)
|
|
||||
| OK | ||
| ||
| 9. CHECK FOR SHORT IN CAN BUS WIRES (NO. 3 JUNCTION CONNECTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY) |
Disconnect the G98 No. 3 junction connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G98-10 (CANH) - G98-21 (CANL)
Engine switch off
200 Ω or higher
G98-10 (CANH) - G48-4 (CG)
Engine switch off
200 Ω or higher
G98-21 (CANL) - G48-4 (CG)
Engine switch off
200 Ω or higher
G98-10 (CANH) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
G98-21 (CANL) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
Text in Illustration *a
Rear view of wire harness connector
(to No. 3 Junction Connector)
*b
Front view of DLC3
|
|
||||
| OK | |
| 10. CHECK FOR SHORT IN CAN BUS WIRES (NO. 3 JUNCTION CONNECTOR - ECM) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G98-9 (CANH) - G98-20 (CANL)
Engine switch off
108 to 132 Ω
G98-9 (CANH) - G48-4 (CG)
Engine switch off
200 Ω or higher
G98-20 (CANL) - G48-4 (CG)
Engine switch off
200 Ω or higher
G98-9 (CANH) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
G98-20 (CANL) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
Text in Illustration *a
Rear view of wire harness connector
(to No. 3 Junction Connector)
*b
Front view of DLC3
|
|
||||
| OK | |
| 11. CHECK FOR SHORT IN CAN BUS WIRES (NO. 3 JUNCTION CONNECTOR - POWER MANAGEMENT CONTROL ECU) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G98-11 (CANH) - G98-22 (CANL)
Engine switch off
108 to 132 Ω
G98-11 (CANH) - G48-4 (CG)
Engine switch off
200 Ω or higher
G98-22 (CANL) - G48-4 (CG)
Engine switch off
200 Ω or higher
G98-11 (CANH) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
G98-22 (CANL) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
Text in Illustration *a
Rear view of wire harness connector
(to No. 3 Junction Connector)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 12. CONNECT CONNECTOR |
Reconnect the G98 No. 3 junction connector.
| NEXT | |
| 13. CHECK FOR SHORT IN CAN BUS WIRES (AIR CONDITIONING AMPLIFIER ASSEMBLY) |
Disconnect the G25 air conditioning amplifier assembly connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G25-11 (CANH) - G25-12 (CANL)
Engine switch off
54 to 69 Ω
G25-11 (CANH) - G48-4 (CG)
Engine switch off
200 Ω or higher
G25-12 (CANL) - G48-4 (CG)
Engine switch off
200 Ω or higher
G25-11 (CANH) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
G25-12 (CANL) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 14. CONNECT CONNECTOR |
Reconnect the G98 No. 3 junction connector.
| NEXT | |
| 15. CHECK FOR SHORT IN CAN BUS WIRES (ECM) |
for 1GR-FE:
Disconnect the G56 ECM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G56-34 (CANP) - G56-33 (CANN)
Engine switch off
108 to 132 Ω
G56-34 (CANP) - G48-4 (CG)
Engine switch off
200 Ω or higher
G56-33 (CANN) - G48-4 (CG)
Engine switch off
200 Ω or higher
G56-34 (CANP) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
G56-33 (CANN) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
Text in Illustration *a
Rear view of wire harness connector
(to ECM)
*b
Front view of DLC3
for 1KD-FTV:
Disconnect the G57 ECM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G57-20 (CANP) - G57-21 (CANN)
Engine switch off
108 to 132 Ω
G57-20 (CANP) - G48-4 (CG)
Engine switch off
200 Ω or higher
G57-21 (CANN) - G48-4 (CG)
Engine switch off
200 Ω or higher
G57-20 (CANP) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
G57-21 (CANN) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to ECM)
*b
Front view of DLC3
| Result |
Proceed to |
| OK (for 1GR-FE) |
A |
| OK (for 1KD-FTV) |
B |
| NG |
C |
|
|
||||
|
|
||||
| A | ||
| ||
| 16. CONNECT CONNECTOR |
Reconnect the G98 No. 3 junction connector.
| NEXT | |
| 17. CHECK FOR SHORT IN CAN BUS WIRES (POWER MANAGEMENT CONTROL ECU) |
Disconnect the G51 power management control ECU connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
G51-12 (CA3P) - G51-11 (CA3N)
Engine switch off
108 to 132 Ω
G51-12 (CA3P) - G48-4 (CG)
Engine switch off
200 Ω or higher
G51-11 (CA3N) - G48-4 (CG)
Engine switch off
200 Ω or higher
G51-12 (CA3P) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
G51-11 (CA3N) - G48-16 (BAT)
Engine switch off
6 kΩ or higher
Text in Illustration *a
Rear view of wire harness connector
(to Power Management Control ECU)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 18. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BATTERY AND GROUND) |
Connect the cable to the negative (-) battery terminal.

- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
Disconnect the G51 power management control ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
G51-5 (GND2) - Body ground
Always
Below 1 Ω
G51-6 (GND) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
G51-1 (AM22) - Body ground
Always
11 to 14 V
G51-2 (AM21) - Body ground
Always
11 to 14 V
| *a |
Rear view of wire harness connector (to Power Management Control ECU) |
|
|
||||