SYSTEM DESCRIPTION
Troubleshooting · Vehicles built from Aug 2013
| HEATED STEERING WHEEL SYSTEM |
The heated steering wheel system heats the steering wheel when the steering heater switch is operated.
The heated steering wheel system uses a thermistor inside of the steering wheel to detect the heater temperature and maintain the set temperature.
The timer function of the heated steering wheel system turns off the heater after a predetermined period of time.
| HEATER CONTROLLER SYSTEM |
Operation description


When the engine switch is on (IG), pressing the steering heater switch illuminates the LED and causes current to be output from the steering controller to the heater of the heated steering wheel. Pressing the steering heater switch again turns off the LED and stops the current from being output.
A thermostat is installed in the steering wheel as a safety mechanism.
The steering heater switch LED will turn off when either of the following occurs: 1) an open or short in the steering wheel thermistor continues for 2 seconds or more; or 2) the steering heater switch is pressed continuously for 10 seconds or more.
If the system returns to normal for 2 seconds or more, the previous operation before the malfunction occurred continues. However, regardless of if a malfunction is detected and the malfunction operation is occurring, or if the system returns to normal, the timer will turn off the heater 30 minutes after the switch was first turned on.
Signal input/output description


Signal
Signal Name
Function
Signal Type
Input
Thermistor input
Input of voltage corresponding to heater temperature
Analog input
Input
Temperature setting input
Input of voltage corresponding to temperature setting
Analog input
Input
Switch operation input
Input of power circuit's latch operation estimate signal
LOW/HI input
Output
LED output
Output to LED
LOW/HI output
Output
Heater output
Output to heater
LOW/HI output
Output
Latch output
Power circuit maintenance
LOW/HI output
Safety function
Content
Operation
When thermistor trouble is detected
Heater turns off
When overheating (175°C (347°F)) of controller is detected
Heater turns off
When load short current (50 A or more) is detected
Heater turns off
When undervoltage (4.5 V) is detected
Heater turns off
OFF timer (30 min.)
After preset time of timer passes, heater off
Reverse voltage protection
Protection circuit operates