FAIL-SAFE CHART
System information · Vehicles built from Aug 2013
| MALFUNCTION DETECTION |
Operation when malfunction is detected
Content
Operation
When thermistor trouble is detected
Heater turns off
When overheating (175°C (347°F)) of controller is detected
Heater turns off
When load short current (50 A or more) is detected
Heater turns off
When undervoltage (4.5 V) is detected
Heater turns off
OFF timer (30 min.)
After preset time of timer passes, heater off
Reverse voltage protection
Protection circuit operates
Malfunction detection conditions
An open or short in the steering wheel thermistor continues for 2 seconds or more.
The steering heater switch is pressed continuously for 10 seconds or more.
Malfunction display
The LED of the steering heater switch turns off.
Restore condition
If the system returns to normal for 2 seconds or more, the previous operation before the malfunction occurred continues. However, regardless of if a malfunction is detected and the malfunction operation is occurring, or if the system returns to normal, the timer will turn off the heater 30 minutes after the switch was first turned on.