INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT AIR FUEL RATIO SENSOR |
Measure the heater resistance according to the value(s) in the table below.

- Standard Resistance (for Bank 1):
Tester Connection
Condition
Specified Condition
1 (HA1A) - 2 (+B)
20°C (68°F)
1.8 to 3.4 Ω
1 (HA1A) - 4 (A1A-)
Always
10 kΩ or higher
- Standard Resistance (for Bank 2):
Tester Connection
Condition
Specified Condition
1 (HA2A) - 2 (+B)
20°C (68°F)
1.8 to 3.4 Ω
1 (HA2A) - 4 (A2A-)
Always
10 kΩ or higher
If the result is not as specified, replace the air fuel ratio sensor.Text in Illustration *A
for Bank 1
*B
for Bank 2
*a
Component without harness connected
(Air Fuel Ratio Sensor)