INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT HEATED OXYGEN SENSOR |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance (for Bank 1):
Tester Connection
Condition
Specified Condition
1 (HT1B) - 2 (+B)
20°C (68°F)
11 to 16 Ω
1 (HT1B) - 4 (E2)
Always
10 kΩ or higher
- Standard Resistance (for Bank 2):
Tester Connection
Condition
Specified Condition
1 (HT2B) - 2 (+B)
20°C (68°F)
11 to 16 Ω
1 (HT2B) - 4 (E2)
Always
10 kΩ or higher
If the result is not as specified, replace the heated oxygen sensor.Text in Illustration *A
for Bank 1
*B
for Bank 2
*a
Component without harness connected
(Heated Oxygen Sensor)
