Generator Signal Circuit
Circuit diagnosis · Vehicles built from Aug 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
When the engine is started, the generator assembly turns on and a voltage pulse signal is generated.This signal is used by the air conditioning amplifier assembly.
The signal expressing the amount of output from the generator assembly is one element of PTC heater control.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - GENERATOR) |
Disconnect the G25 amplifier connector.
Disconnect the D3*1 or C65*2 generator connector.
- *1: for 1GR-FE
- *2: for 1KD-FTV
- *1: for 1GR-FE
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for 1GR-FE Tester Connection
Condition
Specified Condition
G25-25 (ALT) - D3-3 (M)
Always
Below 1 Ω
G25-25 (ALT) - Body ground
Always
10 kΩ or higher
for 1KD-FTV Tester Connection
Condition
Specified Condition
G25-25 (ALT) - C65-3 (M)
Always
Below 1 Ω
G25-25 (ALT) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||