INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT SHIFT SOLENOID VALVE SR |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body
20°C (68°F)
11 to 15 Ω
Text in Illustration *a
Component without harness connected
(Shift Solenoid Valve SR)
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) → Shift solenoid valve SR connector
- Battery negative (-) → Shift solenoid valve SR body
Valve moves and makes an operating noise
- Battery positive (+) → Shift solenoid valve SR connector
| INSPECT SHIFT SOLENOID VALVE SLU AND SLT |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) with a 21 W bulb → Terminal 2
- Battery negative (-) → Terminal 1
Valve moves and makes an operating noise
- Battery positive (+) with a 21 W bulb → Terminal 2
If the result is not as specified, replace the solenoid valve.Text in Illustration *a
Component without harness connected
(Shift Solenoid Valve)
| INSPECT SHIFT SOLENOID VALVE SL1 AND SL2 |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) with a 21 W bulb → Terminal 1
- Battery negative (-) → Terminal 2
Valve moves and makes an operating noise
- Battery positive (+) with a 21 W bulb → Terminal 1
If the result is not as specified, replace the solenoid valve.Text in Illustration *a
Component without harness connected
(Shift Solenoid Valve)
| INSPECT SHIFT SOLENOID VALVE S1 |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body
20°C (68°F)
11 to 15 Ω
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) → Shift solenoid valve S1 connector
- Battery negative (-) → Shift solenoid valve S1 body
Valve moves and makes an operating noise
- Battery positive (+) → Shift solenoid valve S1 connector
If the result is not as specified, replace the solenoid valve.Text in Illustration *a
Component without harness connected
(Shift Solenoid Valve S1)
| INSPECT SHIFT SOLENOID VALVE S2 |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body
20°C (68°F)
11 to 15 Ω
Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) → Shift solenoid valve S2 connector
- Battery negative (-) → Shift solenoid valve S2 body
Valve moves and makes an operating noise
- Battery positive (+) → Shift solenoid valve S2 connector
If the result is not as specified, replace the solenoid valve.Text in Illustration *a
Component without harness connected
(Shift Solenoid Valve S2)