2013-2015 Land Cruiser Prado · Service Manual General

SERVICE DATA

Specifications · Vehicles built from Aug 2013

Glow plug
Standard resistance
Tester condition
condition
Specified condition
Glow plug terminal - Body ground
20 °C (68 °F)
Approximately 1.2 Ω
2.2 kW Type
No-load characteristics
Standard current
120 A or less at 11.5 V
Magnet starter switch assembly
Standard resistance
Tester condition
condition
Specified condition
Terminal 50 - Terminal C
Always
Below 1 kΩ
Terminal 50 - Starter switch body
Always
Below 2 kΩ
Brush length
Standard length
16.5 mm (0.650 in.)
Minimum length
9.0 mm (0.354 in. )
Brush holder
Standard resistance
Tester condition
condition
Specified condition
Positive (+) brush holder - Negative (-) brush holder
Always
10 kΩ or higher
Starter brush holder assembly
Brush spring lead
Standard
27 to 33 N (2.7 to 3.3 kgf, 5.9 to 7.3 lbf)
Minimum
18 N (1.8 kgf, 4.0 lbf)
Starter yoke assembly
Standard resistance
Tester condition
condition
Specified condition
Terminal C - Brush
Always
Below 1 kΩ
Terminal C - Starter yoke Body
Always
10 kΩ or higher
Starter armature assembly
Standard resistance
Tester condition
condition
Specified condition
Segment - Segment
Always
Below 1 kΩ
Segment - Coil Core
Always
10 kΩ or higher
Maximum circle runout
0.05 mm (0.00197 in.)
Standard commutator diameter
35.0 mm (1.38 in.)
Minimum commutator diameter
34.0 mm (1.34 in.)
Standard undercut depth
0.7 mm (0.0276 in.)
Minimum undercut depth
0.2 mm (0.0787 in.)
2.7 kW Type
No-load characteristics
Standard current
180 A or less at 11.5 V
Magnet starter switch assembly
Standard resistance
Tester condition
condition
Specified condition
Terminal 50 - Terminal C
Always
Below 1 kΩ
Terminal 50 - Starter switch body
Always
Below 2 kΩ
Brush length
Standard length
20.5 mm (0.807 in.)
Minimum length
11.0 mm (0.433 in. )
Brush holder
Standard resistance
Tester condition
condition
Specified condition
Positive (+) brush holder - Negative brush holder
Always
10 kΩ or higher
Starter brush holder assembly
Brush spring lead
Standard
34 to 42N (3.5 to 4.3 kgf, 7.7 to 9.5 lbf)
Minimum
19 N (1.9 kgf, 4.2 lbf)
Starter yoke assembly
Standard resistance
Tester condition
condition
Specified condition
Terminal C - Brush
Always
Below 1 kΩ
Terminal C - Starter yoke Body
Always
10 kΩ or higher
Starter armature assembly
Standard resistance
Tester condition
condition
Specified condition
Segment - Segment
Always
Below 1 kΩ
Segment - Coil Core
Always
10 kΩ or higher
Maximum circle runout
0.05 mm (0.00197 in.)
Standard commutator diameter
36.0 mm (1.42 in.)
Minimum commutator diameter
35.0 mm (1.38 in.)
Standard undercut depth
0.7 mm (0.0276 in.)
Minimum undercut depth
0.2 mm (0.0787 in.)
3.0 kW Type
No-load characteristics
Standard current
220 A or less at 11.5 V
Magnet starter switch assembly
Standard resistance
Tester condition
condition
Specified condition
Terminal 50 - Terminal C
Always
Below 1 kΩ
Terminal 50 - Starter switch body
Always
Below 2 kΩ
Brush length
Standard length
21 mm (0.828 in.)
Minimum length
12.0 mm (0.472 in. )
Brush holder
Standard resistance
Tester condition
condition
Specified condition
Positive (+) brush holder - Negative brush holder
Always
10 kΩ or higher
Starter brush holder assembly
Brush spring lead
Standard
28 to 37N (3 to 4 kgf, 6.3 to 8.3 lbf)
Minimum
15 N (2 kgf, 3.4 lbf)
Starter yoke assembly
Standard resistance
Tester condition
condition
Specified condition
Terminal C - Brush
Always
Below 1 kΩ
Terminal C - Starter yoke Body
Always
10 kΩ or higher
Starter armature assembly
Standard resistance
Tester condition
condition
Specified condition
Segment - Segment
Always
Below 1 kΩ
Segment - Coil Core
Always
10 kΩ or higher
Maximum circle runout
0.05 mm (0.00197 in.)
Standard commutator diameter
43.0 mm (1.69 in.)
Minimum commutator diameter
42.0 mm (1.65 in.)
Standard undercut depth
0.7 mm(0.0276 in.)
Minimum undercut depth
0.2 mm(0.0787 in.)
Starter relay
Standard resistance
Tester condition
condition
Specified condition
3 - 5
Battery voltage not applied to terminal 1 and 2
10 kΩ or higher
3 - 5
Battery voltage applied to terminal 1 and 2
Below 1 kΩ
Glow relay
Standard resistance
Tester condition
condition
Specified condition
3 - 5
Battery voltage not applied to terminal 1 and 2
10 kΩ or higher
3 - 5
Battery voltage applied to terminal 1 and 2
Below 1 kΩ
← TORQUE SPECIFICATIONS (from Aug 2013)TORQUE SPECIFICATIONS (from Aug 2013) →