P0489 Exhaust Gas Recirculation Control Circuit Low
Diagnostic trouble codes · Vehicles built from Aug 2014
Also covers:
- P0490 Exhaust Gas Recirculation Control Circuit High
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The EGR actuator is operated by the ECM and opens and closes the EGR valve using gears. The opening angle of the EGR valve is detected by the EGR position sensor, which is mounted on the EGR body.| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Idle the engine for 5 seconds or more |
The EGR actuator current is below 0.5 A for 2.0 seconds during EGR valve operation. (1 trip detection logic). |
|
| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Idle the engine for 5 seconds or more |
An EGR actuator current of 8 A or higher due to a mechanical malfunction, or a Hall IC temperature of 150 to 160°C (302 to 320°F) or higher is detected. (1 trip detection logic): |
|
| DTC No. |
Data List |
| P0489 |
|
| P0490 |
WIRING DIAGRAM
Refer to DTC P042E (Click here).INSPECTION PROCEDURE
- NOTICE:
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- After replacing the fuel supply pump assembly, the ECM needs initialization (Click here).
- After replacing an injector assembly, the ECM needs registration (Click here).
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. INSPECT ELECTRIC EGR VALVE ASSEMBLY |
Inspect the electric EGR valve assembly (Click here).
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (ELECTRIC EGR VALVE ASSEMBLY - ECM) |
Disconnect the electric EGR valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
C127-4 (M+) - C93-6 (EGM+)
Always
Below 1 Ω
C127-5 (M-) - C93-7 (EGM-)
Always
Below 1 Ω
- Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
C127-4 (M+) or C93-6 (EGM+) - Body ground
Always
10 kΩ or higher
C127-5 (M-) or C93-7 (EGM-) - Body ground
Always
10 kΩ or higher
Reconnect the electric EGR valve assembly connector.
Reconnect the ECM connector.
|
|
||||
| OK | |
| 3. REPLACE ECM |
Replace the ECM (Click here).
|
|
||||
| 4. REPLACE ELECTRIC EGR VALVE ASSEMBLY |
Replace the electric EGR valve assembly (Click here).
|
|
||||
| 5. REPAIR OR REPLACE HARNESS OR CONNECTOR |
Repair or replace the harness or connector.
| NEXT | |
| 6. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED |
Connect the intelligent tester to the DLC3.
Clear the DTCs (Click here).
Turn the engine switch off for 30 seconds or more.
Start the engine.
Idle the engine for 5 seconds or more
Enter the following menus: Powertrain / Engine and ECT / DTC.
Confirm that the DTC is not output again.
| NEXT | ||
| ||