U0100 Lost Communication with ECM / PCM "A"
Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
| DTC Code |
DTC Detection Condition |
Trouble Area |
| U0100 |
There is no communication from the ECM. |
|
WIRING DIAGRAM






INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
- HINT:
- Operating the engine switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the CAN main wire and the CAN branch wire.
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the airbag system.
- NOTICE:
- After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
- After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
| NEXT | |
| 2. CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM MAIN WIRE) |
Disconnect the G56*1, G57*2 or G60*3 ECM connector.
- *1: for 1GR-FE
- *2: for 1KD-FTV
- *3: for 2TR-FE


- *1: for 1GR-FE
| *A |
for 1GR-FE |
*B |
for 1KD-FTV |
| *C |
for 2TR-FE |
- |
- |
| *a |
Front view of wire harness connector (to ECM) |
- |
- |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for 1GR-FE Tester Connection
Switch Condition
Specified Condition
G56-34 (CANP) - G56-33 (CANN)
Engine switch off
108 to 132 Ω
for 1KD-FTV Tester Connection
Switch Condition
Specified Condition
G57-20 (CANP) - G57-21 (CANN)
Engine switch off
108 to 132 Ω
for 2TR-FE Tester Connection
Switch Condition
Specified Condition
G60-36 (CANP) - G60-35 (CANN)
Engine switch off
108 to 132 Ω
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND) |
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
for 1GR-FE:
Disconnect the C36, C37 and G55 ECM connectors.


Text in Illustration *a
Front view of wire harness connector
(to ECM)
-
-
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
C36-12 (E1) - Body ground
Always
Below 1 Ω
C37-14 (E01) - Body ground
Always
Below 1 Ω
C37-15 (E02) - Body ground
Always
Below 1 Ω
C37-10 (ME01) - Body ground
Always
Below 1 Ω
G55-12 (EC) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
G55-24 (BATT) - Body ground
Always
11 to 14 V
G55-23 (+B2) - Body ground
Battery positive (+) voltage applied to terminal G55-9 (MREL)
11 to 14 V
G55-22 (+B) - Body ground
Battery positive (+) voltage applied to terminal G55-9 (MREL)
11 to 14 V
for 1KD-FTV:
Disconnect the C93, G57 and G58 ECM connectors.


Text in Illustration *a
Front view of wire harness connector
(to ECM)
-
-
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
C93-1 (E1) - Body ground
Always
Below 1 Ω
C93-12 (E01) - Body ground
Always
Below 1 Ω
C93-13 (E02) - Body ground
Always
Below 1 Ω
C93-8 (ME01) - Body ground
Always
Below 1 Ω
G57-11 (EC) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
G57-23 (BATT) - Body ground
Always
11 to 14 V
G57-17 (+B2) - Body ground
Battery positive (+) voltage applied to terminal G58-11 (MREL)
11 to 14 V
G57-24 (+B) - Body ground
Battery positive (+) voltage applied to terminal G58-11 (MREL)
11 to 14 V
for 2TR-FE:
Disconnect the G59, G60 and C64 ECM connectors.


Text in Illustration *a
Front view of wire harness connector
(to ECM)
-
-
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
C64-5 (E1) - Body ground
Always
Below 1 Ω
C64-11 (E01) - Body ground
Always
Below 1 Ω
C64-12 (E02) - Body ground
Always
Below 1 Ω
C64-13 (ME01) - Body ground
Always
Below 1 Ω
G59-11 (EC) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
G59-17 (BATT) - Body ground
Always
11 to 14 V
G59-23 (+B) - Body ground
Battery positive (+) voltage applied to terminal G60-12 (MREL)
11 to 14 V
| Result |
Proceed to |
| OK (for 1GR-FE) |
A |
| OK (for 1KD-FTV) |
B |
| OK (for 2TR-FE) |
C |
| NG |
D |
|
|
||||
|
|
||||
|
|
||||
| A | ||
| ||