2013-2015 Land Cruiser Prado · Service Manual Engine / Hybrid System

INSPECTION

Inspection · Vehicles built from Aug 2013


INSPECT INTAKE MANIFOLD


NOTICE:
A152702
Do not adjust the adjusting screw or 2 swirl control valve actuator installation bolts.


A152703
  1. Disconnect the 2 vacuum hoses from the actuator.

  1. Check the operation of the swirl control valve.

    1. Check that the valve is fully opened under normal conditions.

    2. Connect the vacuum pumps as shown in the illustration. First apply negative pressure to the diaphragm closer to the intake manifold. This cause the actuator rod to move, which causes the swirl control valve to move. Then, apply negative pressure to the diaphragm on the outer side. This cause the actuator rod to move further, which also causes the swirl control valve to move further. Check that the valve is fully closed when a negative pressure of 65 kPa (488 mmHg, 19.2 in.Hg) is applied.

    3. Wait for 1 minute and check that the vacuum pump needle does not move. If the result is not as specified, replace the intake manifold.

      HINT:
      When applying negative pressure to the diaphragm on the outer side, the diaphragm closer to the intake manifold must be in a vacuum state.


INSPECT VACUUM SWITCHING VALVE (for Swirl Control Valve)

  1. Measure the resistance according to the value(s) in the table below.

    A149922E03

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    33 to 39 Ω
    1 - Body ground
    20°C (68°F)
    1 MΩ or higher
    2 - Body ground

    If the result is not as specified, replace the vacuum control valve set.

  1. Check the operation of the VSV.

    1. A152705E02
      Check that air flows from port E to the filter.
      Text in Illustration 
      *1
      Port E
      *2
      Filter
      *a
      Air
      If the result is not as specified, replace the vacuum control valve set.

  1. A152706E02
    Apply battery voltage across the terminals.
    Text in Illustration 
    *1
    Port E
    *2
    Port F
    *a
    Air

  1. Check that air flows from port E to port F.
    If the result is not as specified, replace the vacuum control valve set.

← REMOVAL (from Aug 2014)INSTALLATION (Aug 2013 – Jul 2014) →