Home › Engine / Hybrid System › 1KD-FTV (STARTING) › STARTING SYSTEM › 2015.06–2020.08
NM27T0E _51 Engine / Hybrid System _053608 1KD-FTV STARTING _0260138 STARTING SYSTEM UN GENERAL/CONTROL/DETAILS F

1KD-FTV STARTING  STARTING SYSTEM  GENERAL/CONTROL/DETAILS  GENERAL  


OUTLINE


a.

A conventional reduction type starter is used.



SPECIFICATION


Model Standard Cold Area Specification
M/T A/T
Rated Output 2.2 kW 2.7 kW 3.0 kW
Rated Voltage 12 V 12 V 12 V
Length*1 203.8 mm (8.02 in.) 213.5 mm (8.41 in.) 230.5 mm (9.07 in.)
Weight 6100 g (13.4 lb) 8400 g (18.5 lb) 10600 g (23.4 lb)
Rotational Direction*2 Clockwise Clockwise Clockwise

HINT:

*1: Length from the mounted area to the rear end of the starter.

*2: Viewed from pinion side.