Home › Power Source / Network › 1GD-FTV (BATTERY / CHARGING) › CHARGING SYSTEM › from 2020.08
NM27T0E _57 Power Source / Network _094214 1GD-FTV BATTERY / CHARGING _0447123 CHARGING SYSTEM CO CONTROL F

1GD-FTV BATTERY / CHARGING  CHARGING SYSTEM  CONTROL  CHARGING CONTROL  


FUNCTION OF MAIN COMPONENTS


Component Function
ECM
·

Detects the electrical load condition.

·

Monitors the battery condition based on the current, battery temperature, state of charge and state of health detected by the battery state sensor assembly.

·

Calculates the request voltage based on the electrical load, state of the battery and various sensors, and sends the request voltage signal to the IC regulator.

·

Controls the voltage generated by the generator assembly.


Generator Assembly IC Regulator Receives request voltage command signals from the ECM and charges the battery.
Battery State Sensor Assembly Detects the current, voltage, temperature, state of charge, state of health and state of function of the battery and outputs the data to the ECM via LIN communication.
Battery Supplies power to the electrical components such as the blower motor, wiper, lights and each ECU.


SYSTEM CONTROL


a.

Basic Control Mode

i.

The ECM decreases the generated voltage during acceleration and increases it during deceleration in order to reduce the amount of engine load caused by the generator assembly, improving fuel efficiency.


ii.

During idling and when driving at a constant speed, the ECM adjusts the generated voltage to bring the current integrated value* closer to the target value.

HINT:

*: Integrated value of the battery input/output current as detected by the battery state sensor assembly.




b.

Constant Voltage Mode

i.

In the following situations, basic control is temporarily suspended and constant voltage control is performed.

1.

Stable operation of certain electrical components is required

(a)

To prevent certain electrical components from operating unstably, basic control mode is suspended and a stable supply of voltage is provided by constant voltage mode.


2.

Stable use the battery

(a)

To prevent battery plates from forming lead sulfate due to repeated charging and discharging, constant voltage control is performed for every 30 hours of charging and discharging to sufficiently charge the battery.

(b)

Constant voltage control is performed when the SOC of the battery is low or the temperature of the battery is high/low to minimize deterioration of the battery.