Home › General › SPECIFICATIONS › 1KD-FTV INTAKE / EXHAUST › 2015.06–2020.08
RM27T0E _V1 General _053654 SPECIFICATIONS _0260308 1KD-FTV INTAKE / EXHAUST F

SPECIFICATIONS  1KD-FTV INTAKE / EXHAUST  SERVICE DATA  


Turbocharger boost pressure Standard pressure 5 to 20 kPa (0.05 to 0.2 kgf/cm2, 0.7 to 2.9 psi)
Intake manifold Vacuum switching valve (for Swirl Control Valve) Standard resistance Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
Turbocharger Axial play of turbine shaft Maximum axial play 0.11 mm (0.00433 in.)
Radial play of turbine shaft Maximum radial play 0.112 mm (0.00441 in.)
Exhaust pipe Compression spring Minimum free length 38.5 mm (1.52 in.)